24
Total weight with filled DHW cylinder
Type AWT-AC
Weight in kg
221.A04
364
221.A07
364
221.A10
367
221.A13
367
Minimum room volume (to
DIN EN 378):
Type AWT-AC
Minimum room
volume in m
3
221.A04
2.7
221.A07
4.9
221.A10
6.1
221.A13
6.1
Minimum clearances
Note
If using the secondary circuit connection
set (accessory), maintain a wall clear-
ance of approx. 80 mm.
Minimum room height h
Installation
h in mm
■
Without
pre-assembly/
DHW connection set
(accessory)
2000
■
With
pre-assembly/DHW
connection set (accessory)
2100
Observe engineering informa-
tion.
Vitocal technical guide
Opening and isolating the internal unit
The cylinder module can be removed
during transport.
!
Please note
Avoid damaging the appliance
during handling.
Never
put weight on the top, front
or side panels of the appliance.
Installation sequence
Installing the internal unit
(cont.)
5600 950 GB
Содержание Vitocal 222-S
Страница 26: ...26 7 8 6 P301 P501 P303 P302 F6 Installation sequence Installing the internal unit cont 5600 950 GB...
Страница 27: ...27 10 9 11 Installation sequence Installing the internal unit cont 5600 950 GB Installation...
Страница 28: ...28 15 2x 16 17 2x 12 14 18 13 X20 Installation sequence Installing the internal unit cont 5600 950 GB...
Страница 29: ...29 2x 4x 6x 4x 22 21 20 19 Installation sequence Installing the internal unit cont 5600 950 GB Installation...
Страница 89: ...89 Opening programming unit 2 2x 1 3 Troubleshooting Repairs 5600 950 GB Service...
Страница 90: ...90 Removing cover from programming unit if necessary 5 4 4x Troubleshooting Repairs cont 5600 950 GB...
Страница 91: ...91 Overview of internal components Internal unit Troubleshooting Repairs cont 5600 950 GB Service...
Страница 142: ...142 5600 950 GB...
Страница 143: ...143 5600 950 GB...