Parameters for utilisation of power generated on site
Parameter
Setting
"Photovoltaics"
Ó
"Enable own energy consumption PV 7E00"
"1"
"Threshold for electrical power 7E04"
"0"
to
"300"
(
≙
0 to 30 kW)
Enable required functions for utilisation of power generated on site
Parameter
Setting
"Photovoltaics"
Ó
"Enable own energy consumption for set DHW temperature 2
7E10"
"1"
"Enable own energy consumption for DHW heating 7E11"
"1"
"Enable own energy consumption for heating water buffer
cyl. 7E12"
"1"
"Enable own energy consumption for heating 7E13"
"1"
"Enable own energy consumption for cooling 7E15"
"1"
"Enable own energy consumption for coolant buffer cylinder
7E16"
"1"
Specify the temperature differential to the selected set value for the chosen function
Parameter
Setting
"Photovoltaics"
Ó
"Raise set DHW cylinder temperature PV 7E21"
"0"
to
"500"
(
≙
0 to 50 K)
"Raise set heating water buffer cylinder temp PV 7E22"
"0"
to
"400"
(
≙
0 to 40 K)
"Raise set room temperature PV 7E23"
"0"
to
"100"
(
≙
0 to 10 K)
"Reduce set room temperature PV 7E25"
"0"
to
"100"
(
≙
0 to 10 K)
"Reduce set coolant buffer cylinder temperature PV 7E26"
"0"
to
"100"
(
≙
0 to 10 K)
Parameters for Smart Grid
Parameter
Setting
"Smart Grid"
Ó
"Enable Smart Grid 7E80"
"1"
Connection to EA1 extension
"4"
Connection to heat pump control
unit
"Smart Grid Enable elec heat 7E82"
"1"
Stage 1
"2"
Stage 2
"3"
Stage 3
Specify the temperature differential to the selected set value for the chosen function
Parameter
Setting
"Smart Grid"
Ó
"Smart Grid set value increase for DHW heating 7E91"
"0"
to
"500"
(
≙
0 to 50 K)
"Smart Grid set value increase for htg wtr buff 7E92"
"0"
to
"400"
(
≙
0 to 40 K)
"Smart Grid set value increase for centr htg 7E93"
"0"
to
"100"
(
≙
0 to 10 K)
"Smart Grid set value decrease for room t cool 7E95"
"0"
to
"100"
(
≙
0 to 10 K)
Commissioning, inspection, maintenance
Commissioning the system
(cont.)
5831412
Содержание Vitocal 222-A
Страница 80: ...80 Fig 64 Maintenance Indoor unit Placing the control unit panel in its service position 5831412 Maintenance...
Страница 92: ...92 Maintenance Checking the fuses cont 5831412 Maintenance...
Страница 102: ...102 0004 0005 0001 0002 0003 0006 0007 Fig 74 Indoor unit parts lists Miscellaneous 5831412 Components...
Страница 104: ...104 Indoor unit parts lists Miscellaneous cont 5831412 Components...
Страница 112: ...112 Outdoor unit parts list 230 V types 221 A04 to A08 Outdoor unit electrical equipment 230 V cont 5831412 Components...
Страница 120: ...120 Outdoor unit parts list 230 V types 221 A10 to A16 Outdoor unit electrical equipment 230 V cont 5831412 Components...
Страница 154: ...154 5831412...
Страница 155: ...155 5831412...