32
Outdoor units
Vitocal 222-A
Type
Cable
Max. cable length
230 V appliances
■
AWOT-M-E
■
AWOT-M-E-AC
221.A04
3 x 2.5 mm
2
29 m
221.A06
3 x 2.5 mm
2
29 m
221.A08
3 x 2.5 mm
2
29 m
221.A10
3 x 2.5 mm
2
20 m
or
3 x 4.0 mm
2
32 m
221.A13
3 x 2.5 mm
2
20 m
or
3 x 4.0 mm
2
32 m
221.A16
3 x 2.5 mm
2
20 m
or
3 x 4.0 mm
2
32 m
400 V appliances
■
AWOT-E
■
AWOT-E-AC
221.A10
5 x 2.5 mm
2
30 m
221.A13
5 x 2.5 mm
2
30 m
221.A16
5 x 2.5 mm
2
30 m
Indoor unit: Routing cables to the wiring chamber
230 V/400 V
< 42 V
Fig. 23
Installation sequence
Electrical connection
(cont.)