71
Required parameters for components
connected on site
Detailed explanations regard-
ing parameters
Service instructions for Vitotronic
200 heat pump control unit
System scheme
Overview of all available system schemes
Component
System scheme
0
1
2
3
4
5
6
11
Heating circuit
A1/HC1
—
X
X
—
—
X
X
—
M2/HC2
—
—
—
X
X
X
X
—
DHW cylinder
X
—
X
—
X
—
X
—
Immersion heater
0
—
0
—
0
—
0
—
Heating water buffer cylinder
—
0
0
X
X
X
X
—
External heat source
0
0
*1
0
*1
0
0
0
0
—
Instantaneous heating water heater
(only type AWB-AC)
X
X
X
X
X
X
X
—
Swimming pool
—
0
0
0
0
0
0
—
Cooling
(only type AWB-AC)
A1/HC1
—
0
0
—
—
0
0
—
M2/HC2
—
—
—
0
0
0
0
—
SKK
0
0
0
0
0
0
0
—
Electricity meter 1-phase/3-phase
0
0
0
0
0
0
0
0
Vitovent
0
0
0
0
0
0
0
0
X Component selected.
0
Component may be added.
*1
Only in conjunction with a heating water buffer cylinder.
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5782 176 GB
Service
Содержание Vitocal 200-S
Страница 80: ...80 Removing cover from programming unit if necessary 5 4 4x Troubleshooting Repairs cont 5782 176 GB...
Страница 81: ...81 Placing the control panel in its service position 4x 1 3 2 Troubleshooting Repairs cont 5782 176 GB Service...
Страница 145: ...145 5782 176 GB...
Страница 146: ...146 5782 176 GB...
Страница 147: ...147 5782 176 GB...