51
Power supply with power-OFF
Power-OFF without on-site load disconnection
The power-OFF signal is connected
directly to the heat pump control unit.
The compressor is "forced" off when
power-OFF is enabled.
Parameter
"Output for instant. heating
water heater at power-OFF 790A"
determines whether and at what stage
an instantaneous heating water heater (if
installed) remains operational during
power-OFF.
Note
Observe the technical connection condi-
tions of the relevant power supply util-
ity.
X3.7
X3.6
C
B
A
H
D
F
G
3
3
4
4
3
3/N
3/N
≈
4
K
kWh
kWh
5
3
(400 V~)
7 (230 V~)
X40
E
Diagram excluding fuses and RCD
A
Heat pump control unit (internal unit,
luster terminals, see chapter "Over-
view of connections: Internal unit")
B
Instantaneous heating water heater
(if installed)
C
Heat pump compressor (external
unit)
D
Heat pump control unit power sup-
ply (see chapter "Heat pump control
unit power supply (230 V~)")
E
Standard tariff meter
F
Backup fuse ripple control receiver
G
Ripple control receiver (contact
open: power-OFF enabled), feed:
TNC system
Installation sequence
Power supply
(cont.)
5782 176 GB