26
Required parameter settings
Parameter
Setting
"System definition"
■
"System scheme 7000"
"6"
"Compressor"
■
"Output compressor stage 5030"
Type AWB/AWB-AC
■ 201.B04:
"4"
■ 201.B07:
"7"
■ 201.B10:
"10"
■ 201.B13:
"13"
"Ext. heat source"
■
"Enable external heat source 7B00"
"1"
■
"Enable external heat source for DHW heating
7B0D"
"1"
DHW heating:
"Time program, DHW heating"
Set time program (see oper-
ating instructions)
"Time program, DHW circulation"
(if a DHW circulation pump is installed)
Set time program (see oper-
ating instructions)
"DHW"
■
"Enable booster heaters for DHW heating 6014" "1"
■
"Enable electric heaters for DHW heating 6015"
"1"
Instantaneous heating water heater
(if installed):
"Electr booster heater"
■
"Enable instantaneous heating water heater
7900"
"1"
■
"Enable instant. heating water heater for central
heating 7902"
"1"
"Cooling"
■
"Cooling function 7100"
"3"
■
"Cooling circuit 7101"
"2"
Remote controls
(if installed):
"Heating circuit 1"
■
"Remote control 2003"
"1"
"Heating circuit 2"
■
"Remote control 3003"
"1"
To call up
"Coding level 1"
for setting
the parameters, see the commissioning
wizard on page 80 and page 81.
Preparing for installation
System example 2, ID: 4605170_1103_04
(cont.)
5604 692 GB
Содержание AWB 201.B04
Страница 88: ...88 Opening the programming unit 1 3 2 2x Troubleshooting Repairs 5604 692 GB...
Страница 89: ...89 Removing cover from programming unit if necessary 5 4 4x Troubleshooting Repairs cont 5604 692 GB Service...
Страница 90: ...90 Placing the control panel in its service position 4x 1 3 2 Troubleshooting Repairs cont 5604 692 GB...
Страница 100: ...100 C B D A Parts lists internal unit Overview of assemblies internal unit 5604 692 GB...
Страница 102: ...102 0001 0005 0006 0004 0002 0008 0003 0007 0008 Parts lists internal unit Casing internal unit cont 5604 692 GB...
Страница 139: ...139 5604 692 GB...