116
Parameter
Code
Delivered condi-
tion
Commis-
sioning
DHW
Set DHW temperature
6000
500 (
≙
50 °C)
Min. DHW temperature
6005
100 (
≙
10 °C)
Max. DHW temperature
6006
600 (
≙
60 °C)
Hysteresis DHW temperature heat pump 6007
70 (
≙
7 K)
Hysteresis DHW temperature booster
heater
6008
100 (
≙
10 K)
Start optimisation for DHW heating
6009
0
Stop optimisation for DHW heating
600A
0
Set DHW temperature 2
600C
600 (
≙
60 °C)
Temperature sensor at bottom of DHW
cylinder
600E
0
Enable booster heaters for DHW heating 6014
0
Enable electric heaters for DHW heating 6015
1
Priority DHW heating with combi cylin-
der
6016
0
Start attempts for DHW after high pres-
sure shutdown
6017
1
Operating mode cylinder primary pump
6020
Never adjust
Electric heater
Enable instantaneous heating water
heater
7900
0
Enable instant. heating water heater for
central heating
7902
1
Max. output instantaneous heating water
heater
7907
3
Output for instant. heating water heater at
power-OFF
790A
0
Dual mode temp. instant. heating water
heater
790B
100 (
≙
10 °C)
Internal hydraulics
Heat pump for drying a building
7300
0
Time program for screed drying
7303
0
Flow temperature for external demand
730C
500 (
≙
50 °C)
Enable 3-way diverter valve heating/
DHW
730D
1
Operating mode secondary pump
7340
Never adjust
Commissioning/service reports
Control parameters report
(cont.)
5601 429 GB
Содержание 7424689
Страница 83: ...83 Opening the programming unit 1 3 2 2x Troubleshooting Repairs 5601 429 GB Service ...
Страница 84: ...84 Removing cover from programming unit if necessary 5 4 4x Troubleshooting Repairs cont 5601 429 GB ...
Страница 85: ...85 Placing the control panel in its service position 4x 2 3 1 Troubleshooting Repairs cont 5601 429 GB Service ...
Страница 86: ...86 Removing the separating plate 1 2 Troubleshooting Repairs cont 5601 429 GB ...