66550062-EN - V 1.1 - 31/05/18
- 8 -
IPVK/6296 Series IP videokit
IPVK/6296 Series - Installation handbook
ENABLE BOOTLOADER MODE
In case of firmware update failure (i.e. because of mains failure or
cable disconnection during the update etc.) and the door panel is
not anymore recognized by the Videx IP Wizard software, you can
try to restore it by manually putting it into boot mode.
It is strongly recommended that this operation is carried out by
a qualified engineer and in any case after a contact with videx
support.
• Disconnect the door panel from the power supply.
• Press and keep pressed the “
J
” button (Fig. 2 on page 5) then
connect again the power supply source.
• The door panel goes in boot mode recognized by the four
LEDs flashing alternatively (Fig. 11).
• Now proceed using the utility “VidexFirmwareUpdater.exe” to
upload the firmware to the device.
• If the update process terminates correctly, the device should
be restored and ready to work.
• If the device still not work, please contact the supplier to proceed according to the warranty terms.
TECHNICAL SPECIFICATION
SIGNALS ON SYSTEM CONNECTION TERMINALS
EXT
CAMERA
SL
Active low output enabled when the
external video input is in use
GND
Composite video signal ground reference
V
Composite video signal input
RS485
A
RS-485 Connection (termination adjusted
through the JP1 jumper)
B
GND
POWER
+12V
12Vdc 400mA power supply input
GND
INPUTS
PTE1
Active low input 1 (when enabled activate
the relay 1)
PTE2
Active low input 2 (when enabled activate
the relay 1)
GNDP
Ground reference to be used with PTE inputs
ETHERNET
RX–
Ethernet Connection Orange (568A)
RX+
Ethernet Connection White/Orange (568A)
TX–
Ethernet Connection Green (568A)
TX+
Ethernet Connection White/Green (568A)
RELAY 2
C2
Relay 2 common contact
Max
12-24
Vac/dc
0.4A
NC2
Relay 2 normally closed contact
NO2
Relay 2 normally open contact
RELAY 1
C1
Relay 1 common contact
NC1
Relay 1 normally closed contact
NO1
Relay 1 normally open contact
UNIT SPECIFICATION
Housing/Mounting:
One 4000 Series Module / 4000 Series
Modular System
Push Buttons:
Yes, from 0 to 2 call buttons depend-
ing on the model
Programming:
Yes, carried out by the 8 way dip-switch
located on the rear of the module
Controls:
Microphone and Loudspeaker volume
trimmers
Front plate finishes:
Mirror stainless steel (standard),
Anodized Aluminium (add /a after the
product code) or High Brass (add /HB)
Power Supply:
12Vdc - 400mA
Power consumption:
Stand-by:
??
mA
Operating:
??
mA
Working Temperature:
-10 +50 °C
Fig. 11
Door panel in BOOTLOADER mode
Art. 4533
IP speaker unit module
Содержание IP videokit IPVK-1/6296