66550062-EN - V 1.1 - 31/05/18
- 11 -
IPVK/6296 Series IP videokit
IPVK/6296 Series - Installation handbook
TECHNICAL SPECIFICATION
Power Supply:
12/24 Vac/dc – 2VA
Power Consumption:
Stand-by: 20mA
Operating: 70mA
Working Temperature:
-10 +50° C
PROGRAMMING FLOW-CHART
ENTER
“ENGINEER’S CODE“
AND PRESS
“ENTER“
CONFIRM OR CHANGE
“ENGINEER’S CODE“
AND PRESS
“ENTER“
ENTER
“ACCESS 1 CODE“
AND PRESS
“ENTER“
ENTER
“ACCESS 1 TIME“
AND PRESS
“ENTER“
ENTER
“ACCESS 2 CODE“
AND PRESS
“ENTER“
ENTER
“ACCESS 2 TIME“
AND PRESS
“ENTER“
ENTER
“ACCESS 3 CODE“
AND PRESS
“ENTER“
ENTER
“ACCESS 3 TIME“
AND PRESS
“ENTER“
SYSTEM READY TO USE
First time 6 times 1 "111111"
factory preset
Type again six times “1”
or the new enginner’s code 4 to 8 digits
Code to enable
relay 1
4 to 8 digits
Code to enable
relay 2
4 to 8 digits
2 digits (01 to 99)
I.E.
05 = 5 seconds
00 = remain open time
2 digits (01 to 99)
I.E.
05 = 5 seconds
00 = remain open time
Code to enable
relay 3
4 to 8 digits
2 digits (01 to 99)
I.E.
05 = 5 seconds
00 = remain open time
Red LED will be ON
Red LED will be OFF
Melody
Melody
Melody
Melody
Melody
Melody
Melody
Art. 4800M
Digital codelock module
Содержание IP videokit IPVK-1/6296