Victoria-05 Ltd.
18
Switching among these is based on the temperature, preset as water heater temperature.
- if the water heater temperature is set to 50°С.
- in the Modulation 5 Menu / the Thermal Difference one should set is 4°С
- in the Modulation 4 Menu / the Thermal Difference one should set is 3°С
- in the Modulation 3 Menu / the Thermal Difference one should set is 2°С
- in the Modulation 2 Menu / the Thermal Difference one should set is 1°С
- in the Modulation 1 Menu / the Thermal Difference one should set is 0°С
Under the parameters set as above, the process will go like this:
On reaching 46°С, which is 4°С below the preset, Modulation 4 will launch.
On reaching 47°С, which is 3°С below the preset, Modulation 3 will launch.
On reaching 48°С, which is 2°С below the preset, Modulation 2 will launch.
On reaching 49°С, which is 1°С below the preset, Modulation 1 will launch.
On reaching the preset temperature, the device will transfer to Stop Mode.
In the Stop Mode, Clean on Extinct Fire will launch.
On passing the time for Clean on Stop, the device would transfer to Green Eco Mode. In
the Eco Mode, there are two important events to emerge.
The first one is for the Time Clock, which has been preset to 600 seconds, to run out, and
only after that the water heater temperature is checked to have decreased down below
the preset one; these two events having taken place, only then can the device transit
again to Start, Fuel, Ignition, etc. Modes...
The Modulations can be changed through pressing the mode display field on which modulation the device is to operate
under!
Meaning, if we are on Modulation 5 on pressing the selection field, it will redirect to Modulation Change Menu.
It is important to note that this change is permanent. It is saved and on restarting the control unit and reaching the
modulations, if Modulation 2 is preset, then the device would transfer to it directly!
12.Maintenance.
Disconnect the power supply of the pellet stove before performing any activity
Vacuum the combustion chamber before each ignition. If the combustion is interrupted, do not light a pellet stove again
until you have emptied and cleaned the combustion chamber.
The wood pellets, which are subtracted from the combustion chamber, should not be put back in the pellet
fuel hopper!
To operate properly, the pellet stove must be regularly serviced. If you do not perform regular maintenance (thorough cleaning
at least once per season), this may lead to improper operation of the pellet stove. Any problems arising from lack of cleaning
lead to void the warranty.
12.1. Daily cleaning.
For better heat transfer and reduce fuel consumption, its needed daily cleaning of soot in flue channels. While pellet stove
works, open the top door and by energetic movements up / down get clean the elements through the channels with the handle
(Fig.6). Suffice cleaning is required once a day. In the manipulation, wear protective gloves.
Fig.6. Fig.7. Fig.8. Fig.9.
Activities to be carried out during the cleaning, only when the pellet stove is cold. Clean the pellet stove with a vacuum cleaner
only when it is completely cold. The procedure takes a few minutes.
-
Open the lower door and throw away the ashes from the ashtray (Fig.7);
-
Open the middle door and remove the combustion chamber or use the spatula to scrape off any scales that clog the
holes (Fig.8);