background image

02.2020

 

 

 

INSTRUCTION MANUAL 

for installation and operation of pellet stove

VITTORIA В*

 

 

 

9

 

 

Safe distances for fire safety: 

When installing a pellet stove and storage of wood pellets, there must be respected with the fire requirements! 

 

It is recommended that an appropriate place to mount a fire extinguisher. 

It is forbidden to store the wood pellets directly to the pellet stove or a distance of less than 400 mm. 

The optimal distance between the pellet stove and combustible materials is 1000 mm. 

Inflammable objects should not be placed on the top board of the pellet stove. 

If the chimney is connected to the timber wall or other inflammable material, suitable materials such as ceramic wool or  similar 
must isolate it. 

Fresh air opening:  

Imperative to ensure submission of fresh air! 

 

The room, in which is mounted pellet stove must have an opening for fresh air with a cross section of not less than 80 cm² in 
order to ensure a sufficient supply of oxygen necessary for combustion. Additionally, it can be delivered outside air  through a 
steel pipe of Ø 50 mm. In this case, there is possibility for emergence of condensate. If necessary, the opening for external air 
can be protected by a grid whose light-section should not be less than 12 cm². Pipe for outside air has to be mounted on the 
nearest outer wall to the pellet stove. Its length should not exceed 1 m, should not have curves and its location has to prevent 
clogging. The outer end of the pipe must end with a knee 90˚, downward or be provided with protection against wind. 

Chimneys: 

Pellet stove works constantly with a fume extractor and pressure in the flue pipes and chimney. 

It is forbidden the flue gases to be discharged directly from the pellet stove through the wall into the atmosphere. Required is 
installed chimney, which takes flue gases to safe for human health altitude over the area of habitation. 

It is recommended that the pellet stove can be installed as close as possible to the chimney in order to reduce the number of 
connecting flue pipes. Pellet stove operates at low temperature regime and it is therefore possible occurrence of condensation 
in the chimney, which requires more frequent inspection and cleaning. 

Chimney should be used only by the pellet stove and no other appliances have to be connected to it. The flue gases are emitted 
from the combustion chamber of the  pellet  stove to the atmosphere through a  flue socket Ø 80 mm located in the rear. It is 
recommended  at  the  beginning  of  the  vertical  section  of  the  chimney  to  mount  a  T-fitting,  with  a  section  for  collecting 
condensate.  Pellet  stove must  be connected to the  chimney by steel  flue pipes,  certified according to EN 1856. The flue pipe 
system must be hermetically insulated with materials resistant to high temperatures (heat-resistant silicone or grease). Allowed 
is to have a horizontal section with a length of 2 m. Horizontal section must be  with minimum slope of 3% and not more than 
two curves at 90°. 

If the flue socket of the pellet stove is connected to a metal chimney, it must have a vertical portion length of not less than 1.5 m 
and fitted with a wind protection. Chimney may be located internally or externally. It should be well insulated. 

If the pellet stove is connected to a masonry chimney, it must be intended for appliances for solid fuel. If the chimney has a size 
larger from Ø150 mm in diameter, internally along its entire length must be installed tube of stainless steel with a diameter of 
Ø150 mm as the free space has to be isolated by masonry. All parts of the chimney should have free access to inspection. At the 
bottom of the chimney must be built manhole allowing opening and cleaning at least once a year. On top of the chimney must 
be installed a wind protection hat, according to current regulations. 

 

 

 

 

 

 

 

 

Fig.4. 

 

 

 

 

 

 

Fig 5. 

 

Содержание Vittoria B

Страница 1: ...INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA...

Страница 2: ...ONTROL UNIT 12 10 2 3 MAIN MENU 13 10 2 4 INSTALLER SETTINGS 15 10 2 5 SERVICE TECHNICIAN SETTINGS 16 11 INSTRUCTION MANUAL 17 11 1 WOOD PELLETS LOADING 17 11 2 WOOD PELLET REFUELING 17 11 3 STARTING...

Страница 3: ...failure of any of its components Safety components are activated without outside interference Necessary for the proper operating of the pellet stove is its proper installation in accordance with the...

Страница 4: ...l data and dimensions Fig 1 Air inlet 50 mm Flue socket 80 mm Main switch with integrated socket for power cable D Circulation pump E Cold water inlet G F Hot water outlet G G Outlet pipe G for safety...

Страница 5: ...xpansion vessel capacity 8 l Cold and hot water inlets dimensions 3 4 Pellet fuel hopper capacity 26 kg Flue socket diameter 80 mm Heating volume 470 m 3 Net weight 268 kg The dimensions of the heated...

Страница 6: ...of the water into the integral boiler and sends information to the control system Hydraulic safety valve Upon reaching a pressure of 3 0 bar the system is activated to emit liquid After discontinuatio...

Страница 7: ...onnect the heating system to the sewer 7 Operating mode Pellet stove works with wood pellets These are cylindrical granules made of pressed wood whose combustion is controlled by an electronic control...

Страница 8: ...cause blockage of the auger and to stop the operation of the pellet stove IF PELLET STOVE BLOCKED THE REASON WILL APPEAR ON THE DISPLAY AND IT WILL BE SAVED Using low quality wood pellets or non manu...

Страница 9: ...lue gases to safe for human health altitude over the area of habitation It is recommended that the pellet stove can be installed as close as possible to the chimney in order to reduce the number of co...

Страница 10: ...eat consumers 10 Three way mixing valve thermostatic 11 Stopcock 12 Filter 13 Manometer 6 bar 14 Built in circulation pump The installation hydraulic diagram is indicative and does not replace the doc...

Страница 11: ...ig 3 This operation must be repeated in the first days of use and when the system is recharged even partially The presence of air in the heating system can aggravate proper operation of the pellet sto...

Страница 12: ...and then it would disappear in this case one can sure that the value has been saved correctly Just in case during the time of saving access to the Back Icon is denied to prevent involuntary interrupt...

Страница 13: ...Fan Should one chose Turns then the fan would transfer to Set the Power Mode Should one chose Flow then the Fan would transfer to Flow Supervise Mode Mode of operation Here Heating Mode is firmly fix...

Страница 14: ...imer ON shall not be active The delayed start is an autonomous one time timer which one can set a particular date and hour on to start the fireplace Its effect is a one time individual one The third o...

Страница 15: ...can be locked in two ways The first one is to hold for more than 3 seconds the Title Page Settings Icon The second one is automatically while transitioning to Standby Mode of the Display in 10 minute...

Страница 16: ...an to operate at 100 in Clean Mode This mode gets active if the contol unit transfers to switch off and extinction of the fireplace 600sec Period Here one cans et the time from 100 to 1000 seconds in...

Страница 17: ...Start Mode In this mode what happens is the so called initial clean which lasts 60 seconds by default The smoke fan is set on maximum speed to clean the ashtray If we would like we can change the tim...

Страница 18: ...are on Modulation 5 on pressing the selection field it will redirect to Modulation Change Menu It is important to note that this change is permanent It is saved and on restarting the control unit and...

Страница 19: ...pump Check sensors Clean check and remove all debris from the ignition system Clean and check the electronic control system Check all electrical cables Clean the pellet fuel hopper and check auger to...

Страница 20: ...given icon Exhaust gases High temperature of the combustion chamber above380 0 To remove the alarm the temperature has to drop below this value The stove continues to work Exhaust gases High temperat...

Страница 21: ...in accordance with current regulations and laws Operation Well dried and of good quality wood pellets Diameter of 6 mm and maximum moisture content of 8 Chimney connecting flue pipes and combustion ch...

Страница 22: ...ellet stove is designed to work with wood pellets with a diameter of 6 mm The use of another type of fuel leads to damage SPARE PARTS CATALOGUE Denomination Denomination 1 Gear motor for auger 17 Fire...

Страница 23: ...02 2020 INSTRUCTION MANUAL for installation and operation of pellet stoveVITTORIA 23...

Страница 24: ...Victoria 05 Ltd 24...

Страница 25: ...internal contact with fire or hot surfaces Pellet stove is equipped with safety components that guarantee lock it automatically in case of failure of any of its components Safety components are activ...

Страница 26: ...ease contact you dealer Any warranty repair of the pellet stove is recorded in the diary of warranty Warranty of the pellet stove is NOT VALID in the following cases Quickly worn out components glass...

Страница 27: ...02 2020 INSTRUCTION MANUAL for installation and operation of pellet stoveVITTORIA 27 DIARY for repairs under warranty Company Receipt date Type of repair Delivery date Carried out...

Страница 28: ...Victoria 05 Ltd 1BIvan Momchilov Str 5100 Gorna Oryahovitsa Republic of Bulgaria phone 359 618 60282 E mail info v05 bg http www v05 bg...

Отзывы: