In case of failure:
- To restart the pellet stove is necessary to wait shutdown procedure is complete. The duration is 10 minutes.
Accompanied with an acoustic signal;
- Do not switch on again the pellet stove before you check and, if necessary, remove the cause of the damage and
before you clean the combustion chamber.
Possible reasons for blocking: indication and decision.
Alarm message
On the right the hour and date of alarm event displays. On
clicking the particular alarm on the left the alarms, occurred
on the particular date and hour, are visualized.
The password to delete the alarms is
7777
. Its first enter
would delete the alarms on the right, the second try would
delete the alarms on the left..
Icon
Designation
Alarm
Description
Pressure
Switch
The Faulty Pressure Switch Icon is It will get active, if the
pressure switch reports too low or too high level for a
period of 60 seconds! On trigering of the alert, the device
would switch to Blocked Mode and would wait until any
human intervention fixes the problem.
In Ready Mode this alert cannot be set active!
When set active, this alert would produce sound signal and
display the given icon.
Exhaust gases
High temperature of the
combustion chamber
(above
380
0
С)
To remove the alarm the temperature has to drop below
this value. The stove continues to work.
Exhaust gases
High temperature of the
combustion chamber
(above
420
0
С)
The alarm is shown when the temperature raised above
420°C. To remove the alarm the temperature has to drop
below this value. The stove goes into stop mode.
Unsuccessful
Ignition
Failed ignition
The alarm is shown if during operation of the stove, the
fume outlet sensor detects lower than the set temperature.
When the alarm is triggered stove shifts to cleaning and
stand-by mode.
Water Jacket
Sensor
High temperature of the
integral boiler
The alarm is shown when the temperature of the integral
boiler reaches 90 degree.
Water Jacket
Sensor
Faulty integral boiler sensor
The alarm is shown when there is a fault in the sensor
"Integral boiler"
Interrupted
Supply
Restarted controller
No fire
Extinguished fire
The alarm is shown if there is no fire during second ignition
attempt. When the alarm is triggered stove shifts to
cleaning and stand-by mode.
Damaged Fan
Fan malfunction
The alarm is shown when the rpm sensor does not receive
signal from the fan for 20 seconds.
General Purpose Alarm
Possible reasons might be
faulty
either of the three
sensors, indoor temperature, reverse combustion, or boiler
sensor.