2.10 Gas Requirements
The customer will provide all gases and pressure regulators. Gases must be of high quality. Pressure regulators
shall be double stage.
Gas
Quality
Minimum Pressure
Flow
O2 (Oxygen)
99.5% Purity
(Liquid recommended)
120 psi
8.3 bar / 827 kPa
75 scfh (2123 l/h)
N2 (Nitrogen)
99.5% Purity
(Liquid recommended)
<1000 ppm O2, <32
ppm H2O)
120 psi
8.3 bar / 827 kPa
180 scfh (5097 l/h)
Compressed
or Bottled Air
Clean, Dry,
Free of Oil (see Note 1)
120 psi
8.3 bar / 827 kPa
185 schf (5238 l/h)
H35 (Argon-Hydrogen)
H35 = 35% Hydrogen,
65% Argon
99.995% Purity
(gas liquid
recommended)
120 psi
8.3 bar / 827 kPa
85 scfh (2406 l/h)
Ar (Argon)
99-995% Purity
(gas recommended)
80 psi
5.5 bar / 550 kPa
55 scfh (1560 l/h)
H2O (W ater)
See Note 2
50 psi (3.5 bar)
See Note 3
10 gph (38 lph)
Ultra-Cut 200 Power Supply: Gas Pressures, Flow s, and Quality Requirements
Note 2
: The tap water source does not need to be deionized, but in water systems with
extremely high mineral content a water softener is recommended. Tap water with high levels of
particulate matter must be filtered.
Note 1:
The air source must be adequately filtered to remove all oil or grease. Oil or grease
contamination from compressed or bottled air can cause fires in conjunction with oxygen.
For filtering, a coalescing filter able to filter to 0.01 microns should be installed as close as
possible to the gas inlets on the Gas Control Module.
Maximum Input Pressure 135 psi (9.3 bar)
2.11 Gas Applications
MATERIAL
PRE-
FLOW
PLASMA SHIELD
PRE-
FLOW
PLASMA SHIELD
PRE-
FLOW
PLASMA SHIELD
Air
Air
Air
Air
O
2
Air
Air
Air
Air
Air
Air
Air
Air
Air
Air
N2
N
2
H
2
0
N2
N
2
H
2
0
N2
H
35
N
2
N2
H
35
N
2
Air
Air
Air
Air
O
2
Air
GAS TYPE
GAS TYPE
Air
Air
Air
Air
55 A
100 A
MILD STEEL
STAINLESS STEEL
ALUMINUM
200 A
GAS TYPE
Air
CUTTING
OUTPUT
O
2
Air
Air
Air
Содержание ULTRA-CUT 200
Страница 4: ...Thispageintentionallyblank...
Страница 8: ...NOTE Section 8 Torch operation is provided separately...
Страница 16: ...ULTRA CUT 200 1 8 Manual 0 5133...
Страница 26: ...Manual No 0 5133 Ultra Cut 200 2 10 SPECIFICATIONS This Page Intentionally Blank...
Страница 53: ...Manual No 0 5133 3 27 INSTALLATION ULTRA CUT 200 Art A 09151 After...
Страница 128: ...Manual No 0 5133 Ultra Cut 200 6 30 Power Supply Parts List ULTRA CUT 200 Intentionally Blank...
Страница 134: ...TORCH INFORMATION 7 6 Manual 0 5056 Ultra Cut 200 ULTRA CUT 200 This page is blank intentionally...
Страница 167: ...This Page Intentionally Blank...