Manual No. 0-5133
3-7
INSTALLATION
ULTRA-CUT 200
Connect Input Power and System Ground Cables
1. Carefully cut back the outer sheath on the primary input power cable to expose the individual wires. Cut back
the insulation on the individual wires. Route the cable upward through leads bracket at the bottom of the rear
panel, then through the connections cover support panel on the rear panel of the power supply.
2. Install stripped end of 3 phase wires into the terminal block L1, L2 and L3.
3. Connect the individual cables as shown. Connect the power cable ground cord to the ground terminal block.
CAUTION
The clear connections cover must remain in place.
4. If required pass a system ground cable (F1) through the last opening in the connections cover support panel
next to the input power cable. Connect the cable to the ground terminal block on the power supply rear panel.
Refer to the Ground Connections Section for full details and procedures on proper system grounding.
PILO
T
WOR
K
TO
RCH
Inp
u
t power c
ab
le
Gro
u
nd Termin
a
l Block
Connection
s
Cover
Su
pport P
a
nel
S
y
s
tem Gro
u
nd C
ab
le
Art # A-07659_AB
to Remote Arc
S
t
a
rter
Connection
s
Cover
Connection P
a
nel
Le
a
d
s
Br
a
cket
to Remote Arc
S
t
a
rter
AC INPUT
S
y
s
tem Gro
u
nd C
ab
le
Inp
u
t power c
ab
le gro
u
nd
L1
L2
L
3
L1
L2
L
3
Содержание ULTRA-CUT 200
Страница 4: ...Thispageintentionallyblank...
Страница 8: ...NOTE Section 8 Torch operation is provided separately...
Страница 16: ...ULTRA CUT 200 1 8 Manual 0 5133...
Страница 26: ...Manual No 0 5133 Ultra Cut 200 2 10 SPECIFICATIONS This Page Intentionally Blank...
Страница 53: ...Manual No 0 5133 3 27 INSTALLATION ULTRA CUT 200 Art A 09151 After...
Страница 128: ...Manual No 0 5133 Ultra Cut 200 6 30 Power Supply Parts List ULTRA CUT 200 Intentionally Blank...
Страница 134: ...TORCH INFORMATION 7 6 Manual 0 5056 Ultra Cut 200 ULTRA CUT 200 This page is blank intentionally...
Страница 167: ...This Page Intentionally Blank...