TM-VE414/415MC_40
REV_D
TM-VE414/415MC
/ Operating and Maintenance Instructions Manual
4.
Lubricate the stabilizer wheel, as shown.
CHECKING AND FILLING GEAR
REDUCER OIL
The gear reducer oil level shall be checked
semi-annually or every 3,000 hours of operation,
whichever comes first. If leakage is present,
repairs shall be made to correct the leak.
NOTE:
The gear reducer’s oil capacity is 75 oz
(2 liters).
Vent Plug
Oil Level and
Oil Fill Plug
1.
Remove the oil level plug from the gear
reducer (refer to drawing below). The oil level
should be even with the bottom of the hole.
2.
To add oil, remove the oil level plug from the
gear reducer and fill to the proper level (refer to
drawing above). Refer to the tag attached to the
gear reducer for the required gear oil.
3.
Re-install the oil level plug. liters).
GEAR REDUCER INPUT SHAFT
Grease
Fitting
Bleeder
Fitting
1.
The gear reducer’s input shaft cover contains
a grease fitting (shown above). This grease
fitting is located on the chain coupling side of
the gear reducer. A bleeder fitting is located
on the center of the gear reducer’s input shaft
cover (shown above).
2.
Lubricate the input shaft bearing after every
40 hours of operation. This fitting must be
lubricated with a No. 2EP Lithium-base grease
until it weeps from the bleeder fitting.
CHECKING AND FILLING HYDRAULIC
OIL
1. Check the hydraulic oil level on a monthly
basis. The level should be 3/4–1 inch/20–25 mm
below the top of the tank. Do NOT over-fill
the tank, since the oil may overflow due to
thermal expansion. Refer to the applicable
“Recommended Lubricants” table for the proper
hydraulic oil.
Содержание VE414MC
Страница 2: ......
Страница 47: ...This page intentionally blank...
Страница 59: ...This page intentionally blank...