EMERGENCY STOP OPERATION
Verify that emergency stop function is
operational during tool setup. Perform the
“PUSH”, “PULL”, and “RESET” actions to test
emergency stop function.
1.
Turn the main power switch on the side of the
tool to the “ON” position.
WARNING
• The motor must not energize until after
the “RESET” button has been pressed.
• If the motor energizes from a cold start
without first pressing the “RESET”
button, discontinue use and contact
Victaulic.
Failure to follow this instruction could result
in serious personal injury.
2.
Press the “RESET” button.
3.
Depress the safety foot switch, confirm tool
operation, then release the safety foot switch.
4.
Push the “EMERGENCY STOP” button and
confirm that this action has cut power to the
motor. Depressing the footswitch, pressing the
start button, or adjusting the selector switch
should have no effect on the state of the tool. All
components should remain off.
WARNING
• The motor must not energize while the
“EMERGENCY STOP” button is activated.
• If the motor can be energized while the
“EMERGENCY STOP” button is activated,
discontinue use and contact Victaulic.
Failure to follow this instruction could result
in serious personal injury.