EMERGENCY STOP OPERATION
Verify that emergency stop function is
operational during tool setup. Perform the
“PUSH”, “PULL”, and “ENABLE” actions to test
emergency stop function.
1.
Turn the power switch on the side of the tool
to the “ON” position.
WARNING
• The motor must not energize until after
the “ENABLE” button has been pressed.
• If the motor energizes from a cold start
without first being enabled, discontinue
use and contact Victaulic.
Failure to follow this instruction could result
in serious personal injury or death.
2.
Press the “ENABLE” button.
3.
Depress the safety foot switch, confirm tool
operation, then release the safety foot switch.
4.
Push the emergency stop button and confirm
that this action has cut power to the motor.
Depressing the footswitch, pressing the enable
button, or adjusting the selector switch should
have no effect on the state of the tool. All
components should remain off.
WARNING
• The motor must not energize while the
emergency stop button is activated.
• If the motor can be energized while the
emergency stop button is activated,
discontinue use and contact Victaulic.
Failure to follow this instruction could result
in serious personal injury or death.
TM-VE268_12
REV_H
TM-VE268
/ Operating and Maintenance Instructions Manual