Seize Enable
Keypads in the Powerplus system may seize control of camera stations from keypads with a lower priority
level if the Seize Enable setting is defined as Enabled. Priority levels are discussed in the next section.
Settings:
Keys:
Default:
Enabled
Disabled
Numeric keypad’s + (plus) key or (minus) key
Disabled
Priority Level
A priority level should be assigned to each keypad in the system. The Powerplus uses priority levels to rank
the ability of each keypad to seize control of a camera station from another keypad. If the Seize Enable
setting is set to Enabled (refer to Seize Enable), any keypad may take control of a camera station currently
being controlled by a keypad with a lower priority level.
Ten priority levels are available. Note that fewer priority levels may be used; for example, it might be
desirable to use only three levels for all the keypads in the system. Whether all ten levels or less are used,
the effect is the same: any keypad whose Seize Enable setting is enabled may seize control of a camera
station from a keypad with a lower priority level.
Note: Priority decreases as priority level number increases; the highest priority level is 00 and the lowest is
09.
Settings:
00 to 09
Keys:
Numeric keypad’s + (plus) key or (minus) key
Default:
00
Auto/Manual
As discussed in
Seize
Enable and
Priority
Level, a keypad can seize control of a camera station from a
keypad with a lower priority level. The Auto/Manual setting specifies whether the seize will occur
automatically or must be initiated by a special command. For example, if Auto is specified, a user at a
keypad with higher priority can automatically seize control of a camera station from a keypad with a lower
priority simply by sending a pan, tilt, or any other command to the station. If Manual is specified, the keypad
with higher priority cannot actually control the camera station and therefore seize the control from a keypad
with a lower priority until the AUX4 key is pressed.
Note:
the speed type is set to
1200 at
the remote keypad, the Auto setting must be chosen.
Settings:
Keys:
Default:
Auto
Manual
Numeric keypad’s + (plus) key or (minus) key
Auto
X897 Rev 1196 Nova Powerplus
Keypad/Receiver
l
21
Содержание NOVA Powerplus VP3466
Страница 17: ...This page intentionally left blank 6 l Preliminary Operations X897 Rev 1196 Nova Powerplus ...
Страница 91: ...This page intentionally left blank 80 l Install Defaults X897 Rev 1196 Nova Powerplus ...
Страница 95: ...This page intentionally lef t blank 84 l Error Messages X897 Rev 1196 Nova Powerplus ...
Страница 97: ...This page in ten tionally left blank 66 l Shipping Instructions X897 Rev 1196 Nova Powerplus ...