Tighten the bolts using torque pattern.
8. RE-MEASURE
8.1 Move the black highlight to the Re-measure icon if
needed.
8.2 Press the “OK” button to select.
Verify selection.
8.3 Rotate sensors back to the starting measuring
position and repeat the process.
9. VERIFY RESULTS & DOCUMENT FINAL
ALIGNMENT
Both the vertical and horizontal misalignment values
are displayed.
Verify the angle & offset values meet or are less than
the tolerances.
Green LED should be on.
9.1 Use the left/right arrow buttons to move the black
highlight to the Save icon if needed.
9.2 Press the “OK” button to select.
9.3 Enter the name of the saved alignment.
Use the left hand key pad to enter up to 17
a
lphanumeric characters.
Use the C button on the right hand key pad to
clear errors.
9.4 Press the “OK” button to save.
Orange & Green LEDs will flash as alignment is
saved.
Saved alignment will display for approximately
5 seconds.
10. EXIT THE PROGRAM AND TURN OFF
10.1 Move the black highlight to the Exit icon.
10.2 Press the “OK” button to select.
10.3 Verify selection and press the “OK” button.
10.4 Move the black highlight to the Off icon.
10.5 Press the “OK” button to select.
U S I N G T H E C L O C K M E T H O D
36