4.1 Rotate the sensors to 9:00.
9:00 is shown graphically on the screen, but
it will not be animated as the sensors rotate.
Remember, in the clock method the inclinometers
are turned off.
Standing behind the Movable Machine looking at
the coupling, 9:00 is located on the left.
You should see both “S” and “M” values in the
boxes at the top of the display.
If you do not, then the lasers are not within the
sensors.
4.2 Press the “OK” button to register the 1st
measurement.
The “S” and “M” values will change to near zero.
The values are displayed in mils.
Do not rotate shafts while the Measuring icon is
displayed.
4.3 Rotate the sensors to approx. 3:00.
3:00 is shown graphically on the screen, but
it will not be animated as the sensors rotate.
Remember, in the clock method the inclinometers
are turned off.
Care should be taken to square the “S” and “M”
sensors to one another if shafts are uncoupled.
You should see both “S” and “M” values in the
boxes at the top of the display.
If you do not, then the lasers are not within the
detectors.
4.4 Press the “OK” button to register the 2nd
measurement.
The “S” and “M” values will not change.
Do not rotate shafts while the Measuring icon is
displayed.
4.5 Rotate the sensors to 12:00.
12:00 is shown graphically on the screen, but
it will not be animated as the sensors rotate.
Remember, in the clock method the inclinometers
are turned off.
Care should be taken to square the “S” and “M”
sensors to one another if shafts are uncoupled.
You should see both “S” and “M” values in the
boxes at the top of the display.
If you do not, then the lasers are not within the
sensors.
4.6 Press the “OK” button to register the 3rd
measurement.
The “S” and “M” values will not change.
Do not rotate shafts while the Measuring icon is
displayed.
5. ALIGNMENT RESULTS
Both the Vertical and Horizontal misalignment values
are displayed.
Displayed values are not live.
The angle and offset values ONLY determine the
alignment condition.