Use the animated rotation guide on the screen.
You should see both “S” and “M” values in the
boxes at the top of the display.
4.6 Press the “OK” button to register the 3rd
measurement.
The “S” and “M” values will not change.
Do not rotate shafts while the Measuring icon is
displayed.
5. ALIGNMENT RESULTS
Both the vertical and horizontal misalignment values are
displayed.
Displayed values are not live.
The angle and offset values ONLY determine the
alignment condition.
Angular Misalignment
Offset Misalignment
Mils per inch
Mils
.001/1"
.001"
RPM
Excellent
Acceptable
Excellent
Acceptable
3600
0.3/1"
0.5/1"
1.0
2.0
1800
0.5/1"
0.7/1"
2.0
4.0
1200
0.7/1"
1.0/1"
3.0
6.0
900
1.0/1"
1.5/1"
4.0
8.0
The three LED lights on the display unit indicate
whether the couplings are within tolerance (green
light), within twice the tolerance (orange light), or more
than twice the tolerance (red).
Displayed foot values are for making corrections.
6. CORRECTING VERTICAL MISALIGNMENT
6.1 Correct the vertical alignment from the results
screen.
6.2 Positive foot values: the movable is high, remove
shims.
6.3 Negative foot values: the movable is low, add shims.
6.4 Leave the bolts loose after adjusting shims.
7. CORRECTING HORIZONTAL
MISALIGNMENT
7.1 Using the right arrow button move the black
highlight to the Shim icon.