Fourth black highlighted box with ? mark.
2.12 Press the “OK” button on the right-hand keypad to
accept the value.
Black highlight will move to the Measure icon in
the lower right corner of the display.
3. SET MACHINE RPM IN TOLERANCE
TABLE & SELECT CLOCK MEASUREMENT
METHOD
3.1 Use the left arrow button on the right hand key pad
to move the black highlight to the Tools icon. Press
the “OK” button to select.
3.2. Use the up arrow button to move the black highlight
to the tolerance table. Press the “OK” button to
select.
3.3. Select the machine RPM using up/down arrow
buttons to highlight the correct RPM. Press the
“OK” button to select.
Use next highest RPM setting if machine RPM is
in between values listed.
3.4 Use down arrow button to move the black highlight
down (the Exit Door icon will be highlighted
),
use right arrow button to move black highlight to
“disable inclinometer” icon. Press “OK” button.
will disappear.
Exit door icon will be highlighted
This step enables “clock” measurement method
3.5 Press the “OK” button to exit tools menu.
4. MEASURE MISALIGNMENT
The sensors should begin at or near the 9:00 position.
Absolute precision to attain each clock position is not
necessary, however care should be taken to square
the “S” and “M” sensors to one another if shafts are
uncoupled.
C H A P T E R 1 0
33