7.2 Press the “OK” button to select.
The GO is now “live” and will display the values
in whatever orientation the sensors are pointing.
To correct horizontal misalignment be sure the
sensors are in the horizontal plane.
Use the on screen guidance to rotate sensors to
horizontal if needed.
7.3 Adjust the feet in the direction of the arrows.
The Angle and Offset values will change as the
feet are adjusted.
The LED will change from Red to Orange to
Green as the angular and offset values are
brought into tolerance.
Green LED indicates alignment in tolerance. It’s
not necessary to adjust the foot values to zero.
Tighten the bolts using torque pattern.
8. RE-MEASURE
8.1 Move the black highlight to the Re-measure icon if
needed.
8.2 Press the “OK” button to select.
Verify selection.
8.3 Rotate sensors back to the starting measuring
position and repeat the process.
9. VERIFY RESULTS & DOCUMENT FINAL
ALIGNMENT
Both the vertical and horizontal misalignment values are
displayed.
Verify the angle and offset values meet or are less than
the tolerances.