Center of post to center of post.
2.2 Enter this dimension into the display unit.
Left most black highlighted box with ? mark.
Use left hand keypad to enter the value as a
decimal.
Use the “C” button on right-hand key pad to
clear errors.
2.3 Press the “OK” button on right-hand key pad to
accept the dimension.
Black highlight will move to the next box with ?
mark.
2.4 Measure the distance from the coupling center to
the “M” sensor to the nearest
1
⁄
8
".
Center of coupling to center of “M” sensor post.
2.5 Enter this dimension into the display unit if different
from the value displayed.
Second black highlighted box.
2.6 Press the “OK” button on the right-hand key pad to
accept the value.
Black highlight will move to the next box with ?
mark.
2.7 Measure the distance from the “M” sensor to the
movable machine front foot to the nearest
1
⁄
8
".
The line parallel to the shaft from the center of
the “M” sensor post to the center of the front
foot bolt.