Open the green latches on either sensor and
slide up or down to aim the laser into the light
grey band on the opposite sensor. Adjusting one
sensor will adjust both.
You should see both “S” and “M” values in the
boxes at the top of the display.
If you do not, then the lasers are not within the
sensors.
Lock the green latches.
2. ENTER DIMENSIONS
2.1 Measure the distance between the “S” and “M”
sensors to the nearest
1
⁄
8
".
Center of post to center of post.
2.2 Enter this dimension into the display unit.
Left most black highlighted box with ? mark.
Use left hand keypad to enter the value as a
decimal.
Use the “C” button on right-hand key pad to
clear errors.
2.3 Press the “OK” button on right-hand key pad to
accept the dimension.
Black highlight will move to the next box with ?
mark.
2.4 Measure the distance from the coupling center to
the “M” sensor to the nearest
1
⁄
8
".
Center of coupling to center of “M” sensor post.
2.5 Enter this dimension into the display unit if different
from the value displayed.
Second black highlighted box.
2.6 Press the “OK” button on the right-hand key pad to
accept the value.
Black highlight will move to the next box with ?
mark.
2.7 Measure the distance from the “M” sensor to the
movable machine front foot to the nearest
1
⁄
8
".
The line parallel to the shaft from the center of
the “M” sensor post to the center of the front
foot bolt.
2.8 Enter this dimension into the display unit.
Third black highlighted box with ? mark.
2.9 Press the “OK” button on the right-hand key pad to
accept the value.
Black highlight will move to the next box with ?
mark.
2.10 Measure the distance from the movable front feet to
rear feet to the nearest
1
⁄
8
".
Center of bolt to center of bolt.
2.11 Enter this dimension into the display unit.
U S I N G T H E C L O C K M E T H O D