26
8.4
Error messages
The table 6 contains a list of the most frequent error states of the boiler.
In case of other error code, it is necessary to call the service.
Error messages
If this symbol is
displayed, it means that
there is a fault in the
equipment. Press the
information button an
read other data.
Maintenance or special
operation
If this symbol is displayed, it
means that there is a service
message or a special operation.
Press the information button an
read other data.
Tab.
№
. 6
Error code
Error description
Cause/solution
10
Short circuit/interruption of the outdoor
temperature sensor
•
Check the outdoor temperature sensor
•
Call the service
50
Short circuit/interruption of the hot water
sensor
•
Check the hot water sensor
•
Call the service
110
The boiler is overheated, the electronic safety
thermostat switched off.
•
Wait until the equipment is cooled down
and switch on it again by pressing the
button Reset
•
In case of repeated occurrence of the
error, contact the service
111
The pump is defect or the thermostatic valves
are closed, a temperature sensor was initiated.
•
Open the thermostatic valves
•
In case of repeated occurrence of the
error, contact the service
119
The water pressure switch was initiated.
•
Check water pressure, and in case of too
low pressure, add water
128
Flame loss during operation
•
Start the boiler again by pressing the
button Reset
•
In case of repeated occurrence of the
error, contact the service
133
The control and regulation unit is blocked.
Possible causes: lack of gas, kindling is not
started
•
Start the boiler again by pressing the
button Reset
•
In case of repeated occurrence of the
error, contact the service