Failures
Failure
Cause
Solution
The boiler doesn't
kindle
The boiler is without voltage
•
Check, whether the supply cord is in the
socket and whether there is voltage in the
socket.
Insufficient or interrupted gas supply
•
Check that the main gas supply and the
shut-off valve of the boiler are opened
There is no requirement for the
heating and how water
•
Check settings of the operation mode
Incorrect date and time setting
•
Set date and time
The boiler is in the summer mode (is
switched off by the outdoor
temperature)
•
The boiler can be initiated by means of
switching-over the operation mode to the
permanent comfort
Low water pressure
•
Fill up water into the system
The space temperature
in the room doesn't
comply with the
requirement
The time diagram of the heating
doesn't comply with the requirement
•
Check and if necessary adjust the setting
of the week day, time and date
•
Change the time program of the heating
The setting Space temperature
doesn't comply with the requirement
•
Check and if necessary adjust the setting
of the space temperature, correct the
parameter 720 Heating curve slope and
Influence of space (parameter of Service
settings)
There is no hot water
heating
Hot water heating is switched off
•
Check and if necessary switching-on the
hot water heating
(see fig. 16 - pos. A)
The comfort required temperature is
too low
•
Check and if necessary adjust the comfort
required temperatures
Incorrect date and time setting
•
Check and if necessary adjust the setting
of the week day, time and date
The hot water sensor has an
insufficient contact with the heater
cladding
•
Check and tighten the hot water sensor
The three-way valve doesn't switch
over
•
Check the connection and switching-over
the three-way valve.
Switching-off at a failure
See table 6
•
See table 6
•
Contact the service
WARNING!!!
The boiler sensors don't fulfill a function of safety equipment. If the floor heating is used, it has to be
protected by an extern thermostat. Otherwise, if the three-way valve is opened, the floor heating may be
damaged.
9
Maintenance
Switch-off the equipment before each cleaning-up.
The surface of the product doesn't require special maintenance. The outer cover of the boiler may be wiped by a
dry clout or a clot wetted in detergent solution. In no case you can clean the boiler surface by dissolution reagents
or with abrasive materials.
During checking tightness of the gas distribution and connecting the valve, it is necessary to be particular
about not wetting the coil of the gas valve!
All other maintenance may be performed by only a contractual service
organization trained by the manufacturer!
The user is obliged to provide regular annual check of the gas boiler. In case of violation of these
conditions, no warranty repairs can be required.
The burner sealing has to be replaced with the interval of 2 years of operation or when damaging.
Use exclusively spare parts approved by the manufacturer in order to guarantee the safety a long term
service life of the boiler.