Battery charger / inverter COMBI-GAMMA
22
090138.02
Chapter 3 Display and wiring
3.1 Upper-Front Panel Display
PB1
PB3
PB2
PB5
PB6
PB7
PB8
PB4
PB9
7
2
1
3
4
8
5
10
6
9
Push Buttons
Push buttons
Name
Description
PB1
RUN/STOP
Combi-Gamma RUN/STOP key
PB2
MODE 1
AC Power as Priority Support
Before changing from one mode to
another, it has to stop running and be in
STOP mode
PB3
MODE 2
INVERTER as Priority Support
PB4
MODE 3
Green Power as Priority Support
PB5
MODE 4
AC Power Charge
PB6
DSPL
Multi-display select key
PB7
ENTER
Data write-in key
PB8
UP ( )
Increment key
Press and keys at the same time
to enable the cursor to move to the left
digit from the current digit.
PB9
DOWN ( )
Decrement key
Note:
When pressing RUN/STOP key, the holding time to remain on the key has to be at least 2 seconds
1.
(initial setting) to activate the RUN or STOP function in order to avoid any accidental pressing on
the RUN/STOP key. The second time can be adjusted in RUN/STOP KeyHoldTime (O2-07).
When changing any of four modes to another mode, Combi-Gamma has to STOP and then
2.
press the desired mode key (MODE 1, MODE 2, MODE 3 or MODE 4). Press and hold the
mode key for at least 5 seconds (initial setting) to activate the mode change this in order to
avoid a change of mode by accidental pressing on of the mode keys. The setting of the hold
time can be adjusted in MODE Key Hold Time (O2-06).
The beep sound, when pressing a key, can be enabled or disabled in
3.
Key Pressed Beep Sel
(O2-01)