Battery charger / inverter COMBI-GAMMA
090138.02
13
1.6.6 3-Phase Operation
The product can also be used in a 3-phase system, see page 28. The batteries
must be connected in accordance with page 26. The following condition conditions
should be complied with in the case of 3-1phase operation:
Only
1.
identical models should be used.
Ensure sufficient battery capacity is available.
2.
Position the products close to each other but ensure there is adequate clearance
3.
for ventilation minimum 20 cm.
The BTS, voltage sensor should preferably be connected all three units (1 Master
4.
unit and 2 Follower units).
Only a single remote control can be connected.
5.
1.7 Grounding
When the input voltage of the Combi-Gamma is not switched through, the neutral of “AC
OUT” is connected to ground by means of a relay. This function can be disabled by con-
stant B2-07 (B2-07=0 Disconnect)
1.8 Remote Control Panel (RCP-4)
The Combi-Gamma can be operated remotely from remote port with the aid of a remote
control panel. For connection of a remote control panel, see page 24.
*Note
: The display panel and operation flow of the remote control panel is exactly the same
as the upper-front display panel.