50
is triggered, the Control Panel will not respond.
Interior with Delay
Away and Home Arm Mode:
When the system is in Away Arm mode, if an “
Interior with Delay
” device is
triggered, the Control Panel will start an Entry Delay countdown timer according to
Entry 1 Delay setting programmed for the user to disarm the system. (please refer
to
5.3.2.4. Area
for detail)
If the delay period expires and no correct PIN code has been entered, the Control
Panel will activate its built-in siren immediately and follow
Entry Timer Extend
setting. (please refer to
5.3.2.4. Area
for detail)
If Entery Timer Extend is set to OFF, the Control Panel will report a
Burglar Alarm
immediately.
If Entery Timer Extend is set to ON, the Control Panel will wait for 30 seconds
before reporting a
Burglar Alarm
. If the panel is disarmed within 30 seconds, no
burglar alarm will be reported.
When the system is in Home Arm mode, if an “
Interior with Delay
” device is
triggered, the Control Panel will not respond.
Away and Home Arm Entry Delay:
When the system is counting down Away Arm Entry Delay Timer, if an “
Interior with
Delay
” device is triggered, the Control Panel will wait until the Entry Timer expires
before activating a “
Burglar Alarm
”. If the system is disarmed before Entry Time
expires, the Control Panel will not respond.
When the system is counting down Home Arm Entry Delay Timer, if an “
Interior
with Delay
” device is triggered, the Control Panel will not respond.
Exit Delay:
When the system is counting down Exit Delay Timer, if an “
Interior with Delay
”
device is triggered, the Control Panel will not respond.
Entry 1 / Entry 2
Away and Home Arm Mode:
When the system is in Away and Home Arm mode, if an “
Entry 1
” or “
Entry 2
”
device is triggered, the Control Panel will start an Entry Delay countdown timer
according to Entry 1 Delay or Entry 2 Delay setting programmed for the user to
disarm the system. (please refer to
5.3.2.4. Area
for detail)
If the delay period expires and no correct PIN code has been entered, the Control
Panel will activate its built-in siren immediately and follow
Entry Timer Extend
setting. (please refer to
5.3.2.4. Area
for detail)
If Entery Timer Extend is set to OFF, the Control Panel will report a
Burglar Alarm
immediately.
If Entery Timer Extend is set to ON, the Control Panel will wait for 30 seconds
before reporting a
Burglar Alarm
. If the panel is disarmed within 30 seconds, no
burglar alarm will be reported.
Away and Home Arm Entry Delay:
When the system is counting down Away or Home Entry Delay Timer, if an “
Entry 1
”
or “
Entry 2
” device is triggered, the Control Panel will wait until the Entry Timer
expires before activating a “
Burglar Alarm
”. If the system is disarmed before Entry
Time expires, the Control Panel will not respond.