17
When the system is in Home
Arm mode, if an “
Interior
”
device is triggered, the Control
Panel will not respond.
Away and Home Arm Entry
Delay:
When the system is counting
down Away Arm Entry Delay
Timer, if an “
Interior
” device is
triggered, a “
Burglar Alarm
” will
be activated immediately and
reported.
When the system is counting
down Home Arm Entry Delay
Timer, if an “
Interior
” device is
triggered, the Control Panel will
not respond.
Exit Delay:
When the system is counting
down Exit Delay Timer, if an
“
Interior
” device is triggered,
the Control Panel will not
respond.
Interior, Follower
Away and Home Arm Mode:
When the system is in Away
Arm mode, if an “
Interior,
Follower
” device is triggered, a
“
Burglar Alarm
” will be
activated immediately and
reported.
When the system is in Home
Arm mode, if an “
Interior,
Follower
” device is triggered,
the Control Panel will not
respond.
Away and Home Arm Entry
Delay:
When the system is counting
down Away Arm Entry Delay
Timer, if an “
Interior, Follower
”
device is triggered, the Control
Panel will wait until the Entry
Timer expires before activating
a “
Burglar Alarm
”. If the system
is disarmed before Entry Time
expires, the Control Panel will
not respond.
When the system is counting
down Home Arm Entry Delay
Timer, if an “
Interior, Follower
”
device is triggered, the Control
Panel will not respond.
Exit Delay:
When the system is counting
down Exit Delay Timer, if a
“
Interior, Follower
” device is
triggered, the Control Panel will
not respond.
Interior with Delay
Away and Home Arm Mode:
When the system is in Away
Arm mode, if an “
Interior with
Delay
” device is triggered, the
Control Panel will start an Entry
Delay countdown timer
according to Entry 1 Delay
setting programmed for the user
to disarm the system. (please
refer to
5.4. Area
for detail)
If the delay period expires and
no correct PIN code has been
entered, the Control Panel will
activate its built-in siren
immediately and follow
Entry
Timer Extend
setting. (please
refer to
5.4. Area
for detail)
If Entery Timer Extend is set to
OFF, the Control Panel will
report a
Burglar Alarm
immediately.
If Entery Timer Extend is set to
ON, the Control Panel will wait
for 30 seconds before reporting
a
Burglar Alarm
. If the panel is
disarmed within 30 seconds, no
burglar alarm will be reported.
When the system is in Home
Arm mode, if an “
Interior with
Delay
” device is triggered, the
Control Panel will not respond.
Away and Home Arm Entry
Delay:
When the system is counting
down Away Arm Entry Delay
Timer, if an “
Interior with
Delay
” device is triggered, the
Control Panel will wait until the
Entry Timer expires before
activating a “
Burglar Alarm
”. If
the system is disarmed before
Entry Time expires, the Control