61
6. Appendix
6.1. Fault Event Description
During operation, when the panel detects faulty events, the panel will log the event and make
reports. Users can check fault events from Fault Display in User Menu. Please refer to
4.13 Fault
Display
.
Fault Event Table
Fault Event
Descriptions
Panel Low Battery
When the battery voltage is low, the panel low battery event is generated
Panel Tamper
The tamper switch on back of the panel is not compressed against the back
cover. This means the panel’s cover is opened and not properly sealed.
SIM Not Inserted
The panel does not have a SIM card inserted in SIM Card compartment.
No GSM Signal
The panel does not have any mobile network signal.
Interference/Jamming
The panel detects radio frequency jamming, which will affect its ability to receive
signal from RF devices (Does not include ZigBee/Z-wave/Wi-fi signal)
Device Low Battery
The accessory device at indicated zone number is low on battery
Device Tamper
The tamper switch of the device at indicated zone number is open
Device Supervision
Failure
The panel was unable to receive supervision signal sent from accessory device
at indicated zone number for the duration of Supervision Timer programmed.
(i.e. If Supervision Timer is set to 12 hours, the panel will generate supervision
failure event after failing to receive supervision signal for 12 hours)