Performance
EFFICIENCY DATA
Air Pressure (MPa)
0.1
0.2
0.3
0.4
0.5
0.6
Air consumption (L/min)
84
140
194
236
298
344
Ion Balance (V)
-2.1
-2.3
-2.1
-1.8
-2.1
-1.4
+ Decay Time (s)
1.5
0.9
0.7
0.6
0.6
0.6
- Decay Time (s)
1.6
0.9
0.7
0.6
0.6
0.5
Noise (dB)
65.2
72.4
77.3
80.5
83.2
85.5
*The measurement values were obtained using the VESSEL measurement environment, so error
could be induced depending on the operation environment.
*The values of Ion balance and decay time are measured at 150mm distance from the nozzle to
Charge plate monitor
*Noise is measured at 1m distance from the nozzle.
Installation
CAUTIONS
IN INSTALLATION
REMEMBER
Use only the included power supply adapter. Use of other adapters may results
in fire, electric shock and static electricity removal trouble.
REMEMBER
Uses an air hose of sufficient withstand pressure performance.
Air hoses of insufficient withstand pressure will rupture and leak air.
REMEMBER
Please connect the plug to the power outlet with a ground terminal.
Using the BBZ-E ungrounded runs the risk of electric shock.
REMEMBER
Install the BBZ-E in the below environment.
Adverse environments cause product deterioration and breakdown.
Humidity: 20~80%RH (No dewing) Temperature: 0~50
˚
C
PROHIBITED
Do not use the BBZ-E in the below environments. Adverse environments
cause product deterioration and breakdown, as well as personal accidents.
Where explosion-proofing is required, where found flammable atmospheres,
high temperature and high humidity, or sharp temperature fluctuations, where
dewing occurs, where possibly wet by water, oil or solvent
PROHIBITED
Do not pull excessively on the tube. Abusive handling can damage the gun and
internally disconnect the power cable and air hose.