background image

 

  Advice to use the BBZ-E for a long time 

 

 
Before starting using the BBZ-E, band the air hose and the power cable 
together with the provided “self-fusion butyl rubber tape”, by bowing the 
power cable as shown in the photograph below. 
It can prevent the air hose and the power cable from scattering, and it 
can also improve durability of the power cable. 
Making an extra space by bowing the power cable reduces the load on 
the connector and the connecting area.   
3 sheets of tape are enclosed. You may band other areas of these cables 
with the remaining 2 pieces, taking into consideration the actual work 
and/or wiring. 

 

 
 
 
 
 
 
 
 
 

 
 

 

The tape should be prepared by the user if additionally needed. The 

provided sheet is made by cutting the following tape to 105 mm in 
length each. 

 

<Recommended article> 

Self-fusion butyl rubber tape No.15 made by NITTO DENKO 
[Size: thickness x width x length] 0.5 mm x 19 mm x 10 m 
 

 

Содержание BBZ-E

Страница 1: ... instruction manual before use Keep it in a safe handy place for future reference Table of Contents For Your Safety P 2 Product Features P 3 Production Specifications P 4 External View P 5 Performance P 6 Installation P 7 Operation P 8 Maintenance P 10 Troubleshooting P 13 Storage P 14 Warranty P 16 ...

Страница 2: ...ion proof construction therefore explosion or fire may occur ROHIBITED Do not use BBZ E in flammable atmospheres The corona discharge can act as an ignition source and cause an explosion or fire ROHIBITED Do not use BBZ E in environments subjected to sharp temperature fluctuations or dewing This kind of environment can lead to breakdown DO NOT WET Do not use BBZ E in highly damp places or anywhere...

Страница 3: ...D blinks when High Voltage Alarming is found in the power supply and output shuts down by the built in transformer Compact and Light Weight High Voltage power supply cable is not necessary High Frequency Voltage Transformer is built in for safety this compact design secures high performance of using this gun pin pointedly over the required spot Power source should be DC24 Voltage Supply to this ma...

Страница 4: ... C 35 65 RH No dewing Distance from target area 50 mm Installation location Non dangerous indoor location Static electricity removal time Refer to the items in the capabilities chart Ion balance Within 10V At 0 3MPa and 150mm Material Casing ABS Hook SUS Electrode Needle Pole Tungsten Accessories Instruction Manual AC Adapter AC Adapter No AD24 ITB E Rated input voltage AC100V 240V 50 60Hz 0 4A TY...

Страница 5: ... External View No BBZ E No AD24 ITB E 5 ...

Страница 6: ...oval trouble REMEMBER Uses an air hose of sufficient withstand pressure performance Air hoses of insufficient withstand pressure will rupture and leak air REMEMBER Please connect the plug to the power outlet with a ground terminal Using the BBZ E ungrounded runs the risk of electric shock REMEMBER Install the BBZ E in the below environment Adverse environments cause product deterioration and break...

Страница 7: ...down The attached adapter is specifically designed for use with the BBZ E Do not use the adapter for any other purpose than to supply power to the BBZ E Connector Align the pin positions on the connector and the BBZ E and plug in firmly Turn the metal ring to be fixed the connector Please tighten the ring with sufficient force to prevent loose Always turn the connector with the metal ring Turning ...

Страница 8: ...Voltage Alarm LED H V ALARM LED lights while high voltage alarm Hook To hang on this gun while not in use Light LED Switch To be used at ON OFF with Light LED Light LED To check if the dust and foreign article stained and or remained Air Tube Inlet Air Tube connecting Out dia 6mm x Inner dia 4mm Power Supply Connector Power Inlet fitting for attached power supply adapter AD24 ITB E 8 ...

Страница 9: ...n the tube Abusive handling can damage the gun and internally disconnect the power cable and air hose PROHIBITED Do the damage the hose or cabling Keep the hose and cabling away from sources of heat REMEMBER Before leaving the workplace return the gun to the specified place REMEMBER Do not use BBZ E if it has a defect OPERATION 1 Confirm that the air tube is connected correctly 2 Plug the power ad...

Страница 10: ...h moisture can result in electric shock or breakdown 1 How to Clean the BBZ E Casing Remove the dirt over the BBZ E with soft and dried cloth Never use alcohol and or thinner solvent and detergent 2 How to Clean the Electrode Needle Electrode cleaning should be practiced after power supply adaptor pulled off electric concent Cleaning order 1 2 Remove the Nozzle 3 Clean the point of the needle with...

Страница 11: ...ver Change it with new needle G 7H and fasten firmly with the same screwdriver Place the Nozzle back 4 Mount the Nozzle firmly If it is too tightly fastened it may damage or break itself but if it is not well fastened this nozzle may pop out due to its air blow power 4 Static Erasing Capacity Check Measure ion balance and charge voltage dampening time using a charge plate monitor Reference IEC6134...

Страница 12: ...rts Standard Nozzle G 7SN Flare Nozzle N 2FN Consent Nozzle N 2TN Silent Nozzle N 2WN Brush G 7B 60mm Brush G 7B 60mm Relay Cable BB ZC5 Electrode needle replacement screwdriver G 7DR Speed Controller G 7SC Micro Filter G 7F 12 ...

Страница 13: ... hot If the BBZ E has been damaged because of dropping or shock UNPLUG POWER CABLE Unplug Power cable if BBZ E has adefect DO NOT DISASSEMBLE Do not disassemble the BBZ E Using the BBZ E when in anything but proper working condition can cause product damage or personal accident Therefore promptly request servicing if trouble occurs For servicing contact the place of purchase 13 ...

Страница 14: ...solvents dust etc Where there is heavy dust or smoke Where possibly wet by water oil chemicals etc Where strong electric or magnetic fields are generated In the following cases contact the place of purchase for servicing Do not service BBZ E yourself as this can be dangerous If the power lamp does not light when the trigger is pulled If the power cable is excessively hot If the power supply adapte...

Страница 15: ...15 ...

Страница 16: ...lect misuse alterations operator error or failure to properly maintain clean or repair products LIMIT OF LIABILITY This electronic static eraser use high voltage corona discharge and should not be used in or near flammable or explosive environments In no event will VESSEL or any seller is responsible or liable for any injury loss or damage direct or consequential whether based in tort or contract ...

Страница 17: ...able Making an extra space by bowing the power cable reduces the load on the connector and the connecting area 3 sheets of tape are enclosed You may band other areas of these cables with the remaining 2 pieces taking into consideration the actual work and or wiring The tape should be prepared by the user if additionally needed The provided sheet is made by cutting the following tape to 105 mm in l...

Отзывы: