Installation
Installation Site
Select a location that is suitable for work and near to an air source and 100-240V AC supply.
Air tube
Use an air tube (OD
φ
6 mm x ID
φ
4 mm) with sufficient withstand pressure.
Please bundle Air tube and Power adapter cord with tape.
Air supply
Remove all impurities with a mist separator (0.3
μ
m). Remove all moisture with an air dryer.
Supply air at a temperature of 0
~
40
˚
C.
Power adapter
Use the attached power adapter. Use with other adapter can lead to breakdown. The attached
adapter is specifically designed for use with the BBZ-E. Do not use the adapter for any other
purpose than to supply power to the BBZ-E.
Connector
Align the pin positions on the connector and the BBZ-E, and plug in firmly.
Turn the metal ring to be fixed the connector.
Please tighten the ring with sufficient force, to prevent loose.
Always turn the connector with the
metal ring
.
Turning the part of the rubber may
cause failure.
Ground
Please connect the plug to the power outlet with a ground terminal.
Before Use Checks
Before use, check the BBZ-E, air tube and power adapter for trouble.
Make sure there is no damage, loose screws, disconnected hosing, loose connectors, etc.