t-line 

Extract Units

Before  a emp ng  to  carry  out  any  maintenance  work,  inves ga ve  or  repair  work  on  our
units,  the  unit  MUST  BE  COMPLETELY  ISOLATED

 

from  its  electrical  supply.  Ensure  a  minimum

of  two  minutes  a er  electrical  disconnec on  before  removing  access  panels.

Warning

Before  a emp ng  to  carry  out  any  work  on  our  units,  all  accompanying  documenta on
including  warning  labels  on  the  unit  must  be  referenced.
Should  it  be  necessary  to  remove  any  component  ensure  that  these  are  secured  into
posi on  once  reinstalled.  It  is  cri cal  that  a er  any  maintenance  work  has  been  conducted
that  all  components  removed/replaced  be  refi ed  correctly  by  a  competent  engineer

Important

In  general,  this  series  of  units  require  li le  maintenance.  Regular  inspec on  for  damage
and  cleaning.  In  the  unlikely  event  of  component  failure,  spares  are  available  from  stock
at  VES.

Ensure  the  unit  has  been  allowed  to  completely  cool  before  a emp ng  any  work  to  the
unit.

Cau on

Ensure  impellor  has  been  allowed  to  completely  stop  before  a emp ng  to  carry  out any
work  on  this  unit.

When  accessing  the  unit  always  use  the  handles  to  ensure  the  access  panels  are
handled/opened  in  a  controlled  manner  so  as  to  avoid  damage  to  the  unit  or  injury  to
personnel.  This  is  par cularly  important  with  bo om  access  units.
Once  maintenance  has  been  carried  out  ensure  the  motor  assembly  is  secured  correctly
before  restar ng  the  unit.

Remove  the  access  panels  and  loosen  the  bolts  holding  the  inlet  eye  in  place   Align  the
inlet  eye  and  impeller  ensuring  the  inlet  eye  is  central  to  the  impeller  and  make  sure  gap

A

’  is  constant.  Hand  gh ten  the  bolts  and  rotate  the  impeller  t o  ensure  the  it  runs

smoothly,  secure  into  posi on  b y  gh tening  the  r etaining  bolts.

Impeller/Inlet Eye

Alignment

The  impeller  should  rotate  freely  and  this  posi on  is  factory  set.  In  the  unlikely  event  of
movement  during  transit  or  opera on  realign  the  impeller  with  the  inlet  eye.

Important

Maintenance

8

A

Fig. 

17

Cau on

Ensure  that  the  clearance  gap  “A”  between  fan  and  inlet  eye  is  constant.  Misalignment
may  cause  undue  wear  on  the  impeller  and  inlet  eye.

Cau on

Содержание t-line 120

Страница 1: ...ginal Instructions Eagle Close Chandlers Ford Industrial Estate Chandlers Ford Eastleigh Hampshire SO53 4NF Tel 44 0 2380 46 11 50 email info ves co uk web www ves co uk Issue G Operation Maintenance...

Страница 2: ...co uk and following the Download O M s link The following symbols used within this document refer to potential dangers advice for safe operation or important points of reference Indicates hazards asso...

Страница 3: ...0 Extract Unit 2 Unit Size 250 350 400 450 500 560 630 710 800 Unit size determined by impellor size 3 Number of motor poles 2 4 6 2 Pole 4 Pole 6 Pole 4 Motor e ciency 1 2 3 IE1 EFF2 IE2 EFF1 IE3 5 P...

Страница 4: ...m must be considered when installing the unit and it is the responsibility of the installer to ensure that all of the equipment is installed in compliance with the manufacturer s recommenda ons with d...

Страница 5: ...ide dependant on the orienta on of the unit Ensure ALL xings are used if reposi oning the feet ensure all xings are reinstated Fixing Feet Installa on Units should only be supported using the support...

Страница 6: ...solator consists of removing the bracket xings re a aching the bracket to the opposite side For units with plugs ensure pins are correctly paired when connec ng the plug to the isolator Warning Handin...

Страница 7: ...panels and loosen the bolts holding the inlet eye in place Align the inlet eye and impeller ensuring the inlet eye is central to the impellor and make sure gap A is constant Hand ghten the bolts and...

Страница 8: ...000 0 0 5 1 1 5 2 2 5 3 3 5 4 4 5 5 5 5 6 6 5 7 7 5 8 8 5 9 9 5 10 10 5 11 pw Di eren al Pressure Pa T LL 35 0 TL L2 50 T L L 4 0 0 T L L 4 5 0 T L L 5 0 0 T L L 5 6 0 T L L 6 3 0 T L L 7 1 0 T L L 8...

Страница 9: ...o carry out any electrical work to our units Warning Motor and electrical details must be checked prior to connec on to electricity supply All motor informa on can be found on the unit data sheet supp...

Страница 10: ...Isolator Wiring Diagram Wiring 6 Con nued Warning Fig 12 For units with plugs ensure pins are correctly paired when connec ng the plug to the isolator Star Connec on Delta Connec on t line Extract Uni...

Страница 11: ...mer connec ons 400 V AC 3 Phase 50Hz 3 Ph 3Ph Inverter Isolator Wiring Diagram Warning Wiring 6 Con nued Fig 13 For units with plugs ensure pins are correctly paired when connec ng the plug to the iso...

Страница 12: ...r Wiring Diagram Star Delta Connec on for units with motors 7 5kW larger Wiring 6 Con nued Fig 14 For units with plugs ensure pins are correctly paired when connec ng the plug to the isolator t line E...

Страница 13: ...Diagram Warning Delta Connec on for units with motors 7 5 kW larger Wiring 6 Con nued Fig 15 For units with plugs ensure pins are correctly paired when connec ng the plug to the isolator t line Extrac...

Страница 14: ...Connec ons for motor thermal cutout safety interlock Easy customer installa on Low cost inverter with IP21 enclosure Suitable for internal loca on Sized to match T Line 3 phase motor Complete with ope...

Страница 15: ...e unit Cau on Ensure impellor has been allowed to completely stop before a emp ng to carry out any work on this unit When accessing the unit always use the handles to ensure the access panels are hand...

Страница 16: ...oling fan on the end of the motor WP units may the require temporary removal of motor cover Con nued In order to remove the motor plate for maintenance remove the xings and secure li ing cable to lugs...

Страница 17: ...ntlement is required due to a blockage ensure motor and impeller are reassembled and installed correctly as in the following diagram For isolator bracket removal refer to page 6 Bush Impellor Top Plat...

Страница 18: ...very month to remove any moisture that may have condensed within the motor T Line units are supplied in both unp ainted and powder coat painted galvanised sheet steel cases Check all painted items to...

Страница 19: ...leigh Hampshire SO53 4NF Tel 44 0 2380 46 11 50 email info ves co uk web www ves co uk VES is a trading name of VES Andover Ltd Registered in England No 02303719 Registered Office as above VES Andover...

Отзывы: