RANGE HOOD - Installation and use instructions

ENGLISH........................................

3

FRANÇAIS...................................

29

Layers Island

ALL-M90BBX
ALL-M90BWX
ALL-E42BBX
ALL-E42BWX

Duo Island

ADL-M90BSX
ADL-E42BSX

Содержание ALL-M90BBX

Страница 1: ...www zephyronline com RANGE HOOD Installation and use instructions ENGLISH 3 FRANÇAIS 29 Layers Island ALL M90BBX ALL M90BWX ALL E42BBX ALL E42BWX Duo Island ADL M90BSX ADL E42BSX ...

Страница 2: ...imum 6 round duct will allow the hood to perform most efficiently 3 Long duct runs elbows and transitions will reduce the performance of the hood Use as few of them as possible 4 Install a roof cap Connect round metal ductwork to cap and work back towards hood location Use duct tape to seal the joints between ductwork sections Fig 7 FIG 7 DUCT COVER HOOD 6 ROUND DUCT ROOF CAP 24 MINIMUM ABOVE COOK...

Страница 3: ...t the flange may already be pre installed Fig 8 2 Remove the blower plate unscrewing the 4 3 9x9 5 mm screws Fig 9 3 Install internal blower into blower plate and secure using 4 screws Fig 10 4 Install assembly blower by means 8 3 9x6 mm screws Fig 11 5 Place the 6 metallic flange provided on the blower s air outlet Fig 12 FIG 8 FIG 9 FIG 10 FIG 12 FIG 11 4 MOUNTING SCREWS Supplied with the motor ...

Страница 4: ...9x9 5 mm screws Fig 13A 2 Make connections B C D Fig 13 3 Remove the wiring box cover Remove a knockout from the wiring box Fig 14E 4 Secure the conduit to the wiring box through a conduit connector 5 Make electrical connections Connect white to white black to black and green to ground 6 Replace wiring box cover and screws Make sure that wires are not pinched between cover and box WIRING BOX COVER...

Страница 5: ...for mounting location suggestions and restrictions 2 A straight short duct run using a minimum 8 round duct will allow the hood to perform most efficiently 3 Long duct runs elbows and transitions will reduce the performance of the hood Use as few of them as possible Larger ducting may be required for best performance with long duct runs 4 After the External or In Line Blower has been installed con...

Страница 6: ...details refer to manual included with the blower 1 Remove the blower plate unscrewing the 4 3 9x9 5 mm screws Fig 15 2 Install the external blower plate and secure using 4 3 9x6 mm screws Fig 16 3 Install 8 round blower collar to top of blower housing screwing the 4 3 9x9 5 mm screws Fig 17 FIG 15 FIG 16 FIG 17 MOUNTING SCREWS 3 9x6mm MOUNTING SCREWS 3 9x9 5mm MOUNTING SCREWS 3 9x6mm ...

Страница 7: ... electrical connections remote blower box marked motor connection Connect white to white black to black blue to blue red to red green to ground Fig 18B 6 Replace the wiring box covers and screws Make sure wires are not pinched between the cover and box External blower connection 1 Make electrical connections at the remote blower see instructions provided with the remote blower REMOTE BLOWER HOOD W...

Страница 8: ...en the 8 screws in the height adjustment holes as necessary Insert 8 screws 3 9x6 mm located in the Hardware Package Fig 19 4 Secure the support frame to joists and cross framing with four 4 screws provided 4 8x38mm Make sure screws are driven into center of joists and framing for maxi mum strength Notes Minimum hood distance above cook top must not be less than 24 TOP VIEW OF SUPPORT FRAME SUPPOR...

Страница 9: ...he air to the outside 3 Tape all duct joints with aluminum duct tape NON DUCTED INSTALLATION ONLY Note a Purchase Model ZRC 01LL Non ducted Recirculating Kit from your local dealer b Rooms with 10 to 12 foot ceiling require duct cover extension support frame model Z1C 02LL available from your local dealer Discard the duct cover extension support frame supplied with the range hood and replace it wi...

Страница 10: ...ith 4 3 9 x 9 5 mm screws Fig 24 Vents may be exposed on 10 to 12 foot ceilings 2 Secure the two lower duct covers parts to the support frame by overlapping the lateral magnets Fig 25 FIG 24 FIG 25 UPPER DUCT COVER MOUNTING SCREWS 3 9x9 5mm LOWER DUCT COVER LOWER DUCT COVER MAGNETS ...

Страница 11: ... filter into place and release tab Make sure the filter is securely engaged after installation NON DUCTED HOODS ONLY 1 To remove the CHARCOAL filter grip and push filter tab toward rear of hood Pull the filter down to disengage the rear filter tabs Fig 27 2 To install the CHARCOAL filter align filter in rectangular opening Push filter against springs in rear of hood and press into place Make sure ...

Страница 12: ...00031 Metal Mesh Filter ALL 50200033 OPTIONAL ACCESSORIES Recirculating Kit ADL ALL ZRC 01LL Replacement Charcoal Filters ADL ALL Z0F 01AC Extension Flue up to 12 ADL ALL Z1C 02LL To order parts visit us online at http store zephyronline com or call us at 1 888 880 8368 ...