t-line 

Extract Units

VES  offer  a  range  of  controls  suited  for  the  control  of  selected  motors  used  on  the  T-Line
range.  Three  phase  speed  controllers  use  frequency  drivers  that  offer  0-100%  stepless
control  from  a  wide  range  of  input  signals.

Note: 

Inverters  can  cause  interference  to  nearby  electronic  equipment  and  must  be

installed  correctly  to  avoid  this  happening.

Inverter  with  comprehensive  range  of
func ons  and  IP54  enclosure.

Sized  to  match  T-Line  3  phase  motor.

Complete  with  opera onal  keypad.

Op onal  advanced  keypad  with  built-in

me  clock.

IP54  protec on  for  indoor  or  external  use.

BMS  control,  remote  pot,
temperature,  constant  pressure,  humidity
and  CO2/VOC  control.

Main  isola ng  switch  with  lockable  handle.

Panel  live  indicator.

Damper  control.

Volt  free  run  and  trip  indic a on.

Connec ons  for  motor  thermal  cutout  safety
interlock.

Easy  customer  installa on.

Low  cost  inverter  with  IP21  enclosure.
Suitable  for  internal  loca on.

Sized  to  match  T-Line  3
phase  motor.

Complete  with  opera onal
keypad.

IP21/NEMA1  protec on  for
indoor  use.

On/off  control  at  inverter  pad
with  built-in  pot  for  easy
adjustment,  and  BMS
control.  Remote  pot  control
available  (CFSC1).

IP21  Inverter

IP54   Inverter

IP21  Inverter  Specifica on

IP54  Inverter  Specifica on

The  electrical  supply  must  be  fully  isolated  before  a emp ng  to  complete  any  work  on
this  unit.  All  electrical  connec ons,  to  any  unit,  must  be  carried  out  in  accordance  with  the
current  edi on  of  the  I.E.E  Regula ons,  and  only  competent  Electricians  should  be  allowed
to  carry  out  any  electrical  work  to  our  units.

Warning

Controls

7

Important

For informa on regarding associated components (speed controllers, controls) please
refer to the relevant accompanying O&M

Fig. 

16

Important

An  Inverter  Speed  controller  is  required  for  the  opera on  of  this  fan

Содержание t-line 120

Страница 1: ...ginal Instructions Eagle Close Chandlers Ford Industrial Estate Chandlers Ford Eastleigh Hampshire SO53 4NF Tel 44 0 2380 46 11 50 email info ves co uk web www ves co uk Issue G Operation Maintenance...

Страница 2: ...co uk and following the Download O M s link The following symbols used within this document refer to potential dangers advice for safe operation or important points of reference Indicates hazards asso...

Страница 3: ...0 Extract Unit 2 Unit Size 250 350 400 450 500 560 630 710 800 Unit size determined by impellor size 3 Number of motor poles 2 4 6 2 Pole 4 Pole 6 Pole 4 Motor e ciency 1 2 3 IE1 EFF2 IE2 EFF1 IE3 5 P...

Страница 4: ...m must be considered when installing the unit and it is the responsibility of the installer to ensure that all of the equipment is installed in compliance with the manufacturer s recommenda ons with d...

Страница 5: ...ide dependant on the orienta on of the unit Ensure ALL xings are used if reposi oning the feet ensure all xings are reinstated Fixing Feet Installa on Units should only be supported using the support...

Страница 6: ...solator consists of removing the bracket xings re a aching the bracket to the opposite side For units with plugs ensure pins are correctly paired when connec ng the plug to the isolator Warning Handin...

Страница 7: ...panels and loosen the bolts holding the inlet eye in place Align the inlet eye and impeller ensuring the inlet eye is central to the impellor and make sure gap A is constant Hand ghten the bolts and...

Страница 8: ...000 0 0 5 1 1 5 2 2 5 3 3 5 4 4 5 5 5 5 6 6 5 7 7 5 8 8 5 9 9 5 10 10 5 11 pw Di eren al Pressure Pa T LL 35 0 TL L2 50 T L L 4 0 0 T L L 4 5 0 T L L 5 0 0 T L L 5 6 0 T L L 6 3 0 T L L 7 1 0 T L L 8...

Страница 9: ...o carry out any electrical work to our units Warning Motor and electrical details must be checked prior to connec on to electricity supply All motor informa on can be found on the unit data sheet supp...

Страница 10: ...Isolator Wiring Diagram Wiring 6 Con nued Warning Fig 12 For units with plugs ensure pins are correctly paired when connec ng the plug to the isolator Star Connec on Delta Connec on t line Extract Uni...

Страница 11: ...mer connec ons 400 V AC 3 Phase 50Hz 3 Ph 3Ph Inverter Isolator Wiring Diagram Warning Wiring 6 Con nued Fig 13 For units with plugs ensure pins are correctly paired when connec ng the plug to the iso...

Страница 12: ...r Wiring Diagram Star Delta Connec on for units with motors 7 5kW larger Wiring 6 Con nued Fig 14 For units with plugs ensure pins are correctly paired when connec ng the plug to the isolator t line E...

Страница 13: ...Diagram Warning Delta Connec on for units with motors 7 5 kW larger Wiring 6 Con nued Fig 15 For units with plugs ensure pins are correctly paired when connec ng the plug to the isolator t line Extrac...

Страница 14: ...Connec ons for motor thermal cutout safety interlock Easy customer installa on Low cost inverter with IP21 enclosure Suitable for internal loca on Sized to match T Line 3 phase motor Complete with ope...

Страница 15: ...e unit Cau on Ensure impellor has been allowed to completely stop before a emp ng to carry out any work on this unit When accessing the unit always use the handles to ensure the access panels are hand...

Страница 16: ...oling fan on the end of the motor WP units may the require temporary removal of motor cover Con nued In order to remove the motor plate for maintenance remove the xings and secure li ing cable to lugs...

Страница 17: ...ntlement is required due to a blockage ensure motor and impeller are reassembled and installed correctly as in the following diagram For isolator bracket removal refer to page 6 Bush Impellor Top Plat...

Страница 18: ...very month to remove any moisture that may have condensed within the motor T Line units are supplied in both unp ainted and powder coat painted galvanised sheet steel cases Check all painted items to...

Страница 19: ...leigh Hampshire SO53 4NF Tel 44 0 2380 46 11 50 email info ves co uk web www ves co uk VES is a trading name of VES Andover Ltd Registered in England No 02303719 Registered Office as above VES Andover...

Отзывы: