The  T-Line  is  a  range  of  direct  drive  duct  mounted  extract  fans,  designed  typically  for
arduous  condi ons  i.e  hot  air  with  high  grease  content.  The  standard  ambient  opera ng
temperature  of  the  unit  is  -20  to  +35°C,  with  in-duct  airflow  temperature  up  to  120°C.

For  further  technical  details  regarding  dimensions  and  weights,  contact  VES   andover  Ltd.  on

08448  15  60  60, 

quo ng  the  sales  order  (SO)  number  and  the  unit  type  as  found  on  the  unit

name  plate  or  visit 

www.ves.co.uk

.

Introduc on

Nomenclature

1

2

1

Product

TLL

T-Line  120  Extract  Unit

2

Unit  Size

250
350
400
450
500
560
630
710
800

Unit  size  determined  by
impellor  size

3

Number  of  motor
p o l e s

/2
/4
/6

2  Pole
4  Pole
6  Pole

4

Motor  effciency

1
2
3

IE1  (EFF2)
IE2  (EFF1)
IE3

5

Phase

-3

Three  Phase

9

Powder  coat  type

Null

/IT
/BT

Galvanised  plantroom/RAL7004
weatherproof
Internally  only  as  colour
Both  internally  and  externally
coated  as  colour

6

Unit  configura on

/PH
/PL
/WH
/WL

Plantroom  straight  through
Plantroom  c/w  bo om  inlet
Weatherproof  straight  through
Weatherproof  c/w  bo om  inlet

8

Colour

Null

R7004

Galvanised  plantroom  /
RAL7004  weatherproof
Powder  coat  finish  to  any  colour

1

2

3

4

5

6

8

9

TLL

350

/4

1

/BT

/PH

/R7004

7 Enclosure

Op ons

Null
/AE

Standard  configura on
Acous c  Enclosure

7

t-line 

Extract Units

Important

An  Inverter  Speed  controller  is  required  for  the  opera on  of  this  fan

Содержание t-line 120

Страница 1: ...ginal Instructions Eagle Close Chandlers Ford Industrial Estate Chandlers Ford Eastleigh Hampshire SO53 4NF Tel 44 0 2380 46 11 50 email info ves co uk web www ves co uk Issue G Operation Maintenance...

Страница 2: ...co uk and following the Download O M s link The following symbols used within this document refer to potential dangers advice for safe operation or important points of reference Indicates hazards asso...

Страница 3: ...0 Extract Unit 2 Unit Size 250 350 400 450 500 560 630 710 800 Unit size determined by impellor size 3 Number of motor poles 2 4 6 2 Pole 4 Pole 6 Pole 4 Motor e ciency 1 2 3 IE1 EFF2 IE2 EFF1 IE3 5 P...

Страница 4: ...m must be considered when installing the unit and it is the responsibility of the installer to ensure that all of the equipment is installed in compliance with the manufacturer s recommenda ons with d...

Страница 5: ...ide dependant on the orienta on of the unit Ensure ALL xings are used if reposi oning the feet ensure all xings are reinstated Fixing Feet Installa on Units should only be supported using the support...

Страница 6: ...solator consists of removing the bracket xings re a aching the bracket to the opposite side For units with plugs ensure pins are correctly paired when connec ng the plug to the isolator Warning Handin...

Страница 7: ...panels and loosen the bolts holding the inlet eye in place Align the inlet eye and impeller ensuring the inlet eye is central to the impellor and make sure gap A is constant Hand ghten the bolts and...

Страница 8: ...000 0 0 5 1 1 5 2 2 5 3 3 5 4 4 5 5 5 5 6 6 5 7 7 5 8 8 5 9 9 5 10 10 5 11 pw Di eren al Pressure Pa T LL 35 0 TL L2 50 T L L 4 0 0 T L L 4 5 0 T L L 5 0 0 T L L 5 6 0 T L L 6 3 0 T L L 7 1 0 T L L 8...

Страница 9: ...o carry out any electrical work to our units Warning Motor and electrical details must be checked prior to connec on to electricity supply All motor informa on can be found on the unit data sheet supp...

Страница 10: ...Isolator Wiring Diagram Wiring 6 Con nued Warning Fig 12 For units with plugs ensure pins are correctly paired when connec ng the plug to the isolator Star Connec on Delta Connec on t line Extract Uni...

Страница 11: ...mer connec ons 400 V AC 3 Phase 50Hz 3 Ph 3Ph Inverter Isolator Wiring Diagram Warning Wiring 6 Con nued Fig 13 For units with plugs ensure pins are correctly paired when connec ng the plug to the iso...

Страница 12: ...r Wiring Diagram Star Delta Connec on for units with motors 7 5kW larger Wiring 6 Con nued Fig 14 For units with plugs ensure pins are correctly paired when connec ng the plug to the isolator t line E...

Страница 13: ...Diagram Warning Delta Connec on for units with motors 7 5 kW larger Wiring 6 Con nued Fig 15 For units with plugs ensure pins are correctly paired when connec ng the plug to the isolator t line Extrac...

Страница 14: ...Connec ons for motor thermal cutout safety interlock Easy customer installa on Low cost inverter with IP21 enclosure Suitable for internal loca on Sized to match T Line 3 phase motor Complete with ope...

Страница 15: ...e unit Cau on Ensure impellor has been allowed to completely stop before a emp ng to carry out any work on this unit When accessing the unit always use the handles to ensure the access panels are hand...

Страница 16: ...oling fan on the end of the motor WP units may the require temporary removal of motor cover Con nued In order to remove the motor plate for maintenance remove the xings and secure li ing cable to lugs...

Страница 17: ...ntlement is required due to a blockage ensure motor and impeller are reassembled and installed correctly as in the following diagram For isolator bracket removal refer to page 6 Bush Impellor Top Plat...

Страница 18: ...very month to remove any moisture that may have condensed within the motor T Line units are supplied in both unp ainted and powder coat painted galvanised sheet steel cases Check all painted items to...

Страница 19: ...leigh Hampshire SO53 4NF Tel 44 0 2380 46 11 50 email info ves co uk web www ves co uk VES is a trading name of VES Andover Ltd Registered in England No 02303719 Registered Office as above VES Andover...

Отзывы: