Chapter 3 Web Interface of RDU501
97
RDU501 Intelligent Monitoring Unit User Manual
3.
If the binding sequence number is not entered, the system will bind the serial number of the first two mobile devices logged in
from the APP.
4.
After binding, the system only allows the bound mobile terminal to access the RDU501 from the APP. If you want to re-bind,
just modify or delete the binding serial number.
5.
The phone number and email address cannot be empty at the same time.
Delete user
Click the delete icon on the right side of the user list, the dialog box for confirming the deletion will pop up, click the
OK
button to delete the selected user.
Note
Admin user cannot be deleted.
Modify users
1. Click the edit icon to the right of the user list to open the modify user page.
2. Modify user information;
3. Click the
Save
button to save the modified user information.
Users who log in to the RDU501 can be divided into four user groups. They have different security levels and user
authorities. For details, see Table 3-5.
Table 3-5 User security level
Security
levels
User group
User authorities
Level A
Administrator
The administrator has full rights: send control commands to the intelligent device; browse, control,
modify parameters; upload and download files; modify, add, and delete user information; air
conditioner teamwork control parameter settings; system firmware upgrade; modify account validity
period; unlock locked User account
Level B
Engineer
The engineer has the following rights: Send control commands to the intelligent device; Browse,
control, modify parameters; download files; modify own user information (except account validity
period and lock status)
Level C
Operator
The operator can send control commands to the intelligent device
Level D
Viewer
All users can view device information
The
SMS/Telephone Alarm Notification
Test and the
Email Alert Notification
Test can be performed on the
Modify User Information page.
Before using this test function, you need to configure the SMS module and mail server for the current user. For
details, see
Configuration Management
in
3.4.8
.
SMS/telephone alarm notification test
Enter the phone number and click the
SMS/Telephone Alert Notification Test
button to test if the current user's
phone number is connected. If the user receives a test message and a phone call, the test is successful. Otherwise,
the test fails. Please check if the current user's phone number is correct and the SMS MODEM connection is correct.
Email alert notification test
Enter the
Email address
and click the
Email Alert Notification Test
button to test if the current user's email address
is correct. If you receive a test email, the test is successful, otherwise the test has failed. Please check if the above
information is entered correctly.
Note
When adding or modifying users, you must enter a phone number or email address, otherwise the settings cannot be completed.
System Upgrade
Click the
System Upgrade
submenu under the
System Settings
menu to bring up the page shown in Figure 3-145.