40
40
Radiance
®
Direct Vent Gas Heater
30004967
Table 3. Air Shutter Adjustment
Natural Gas
Natural Gas
LP
Model
High Altitude
RADVT/RADVTCS
1/” Open
1/” Open
1/” Open
Table 4. High Altitude Orifice
[Required for altitudes above 000’ (610 m) up to 4500’ (1,370 m)]
Input (BTU/h)
Model
Orifice
Part #
Minimum Maximum
RADVT/RADVTCS #33 / 0.113” 001554
5,000 36,000
(Natural gas only)
Table 2. Injector Orifice Size Matrix
Conversion to Natural Gas
Input (BTU/h)
Model
Kit #
Orifice
Part #
Minimum Maximum
RADVT
001899
RADVTCS
0300166
#31 / 0.10” 000697
5,000 38,000
Conversion to LP
Input (BTU/h)
Model
Kit #
Orifice
Part #
Minimum Maximum
RADVT
00179
RADVTCS
0300165
1.75 mm
001946
5,000 36,000
*LP models do not need re-orificed up to 4500’ (1,370 m) above sea level.