7
Radiance
®
Direct Vent Gas Heater
30004967
Parallel Installation:
Minimum Clearance and Flue Centerline
Fig. 3
Parallel installation, minimum back and side clear-
ances, and flue centerlines.
ST130
34
ALCOVESPECS
42" (1070mm)
Min. Alcove Width
48"
(1220mm)
Max. Alcove
Depth
6"
(150mm)
6"
(150mm)
4" (102mm)
ST19
34
CORNERSPECS
18"
(457mm)
18"
(457mm)
6"
(150mm)
6"
(150mm)
#,
#,
Corner Installation:
Minimum Clearance and Flue Centerline
Fig. 4
Corner installation, minimum corner clearances and
flue centerline.
Wall Centerline from Floor
ST131b
Stardance
wall thimble
9/28/00 djt
A
A
Effective Minimum
Centerline
57” (1448 mm)
(Vermont Castings Group Pipe)
55” (1399 mm) (DuraVent Pipe)
ST131b
Fig. 5
Minimum wall centerline.
Direct Vent Only
Hearth Requirements
The Radiance Heater must be installed on rigid flooring.
When the heater is installed directly on any combustible
surface other than wood flooring, a metal or wood panel
extending the full width and depth of the unit must be used
as the hearth. There are no other hearth requirements.
*
needed for installing DuraVent Minimum Vent Kit #79 or
Vermont Castings Group Minimum Vent Kit #7TFSMSK.
A
C
D
ST101b
Stardance
Direct Vent
Min. Clrnc
9/28/00 djt
B
A: Rear Wall
4” (10 mm)
B: Min. Clearance
44” (1118 mm)*
C: Min. Alcove Height
7” (1830 mm)*
D: Max. Alcove Depth
48” (10 mm)
Sidewall Clearance
6” (150 mm)
ST101b
Fig. 6
Dimensions and clearances to ceiling or alcove.
Direct Vent Only
Wall and Ceiling Clearances