37
Radiance
®
Direct Vent Gas Heater
30004967
Conversion Precautions
Before proceeding, turn control knob on valve to OFF and
turn gas supply OFF. Turn OFF any electricity that may be
going to the appliance.
Fuel Conversion Instructions
WARNING! This conversion kit shall be installed
by a qualified service agency in accordance with
the manufacturer’s instructions and all applicable
codes and requirements of the authority having ju-
risdiction. If the information in these instructions is
not followed exactly, a fire, explosion or production
of carbon monoxide may result causing property
damage, personal injury or loss of life. The qualified
service agency is responsible for the proper instal-
lation of this kit. The installation is not proper and
complete until the operation of the converted appli-
ance is checked as specified in the manufacturer’s
instructions supplied with the kit.
CAUTION: The gas supply shall be shut off prior to
disconnecting the electrical power, before proceed-
ing with the conversion.
ST226
attach gas line
12/8/99 djt
PILO
T
ON
OFF
PILO
T
AD
J
LO
HI
Main
Gas Line
Gas Supply Inlet
ST6a
Fig. 70
Attach the gas line to the right side of the valve.
Conversion Procedure
1. Remove stove front. Lift stove front up and then swing
bottom out and away to disengage from the stove body.
(Page 6, Fig. 46)
. Undo the right and left latches at the top of the glass
frame. (Page 6, Fig. 47)
3. Pull the top edge of the glass and frame assembly away
from the firebox face. Place the assembly out of the way
on a flat, padded surface such as a counter protected
by a towel.
4. Remove the logset from the firebox.
Valve Conversion
RADVT Series Models
1. Turn control knob to the OFF position, and shut off the
gas supply to the valve.
. Allow the valve to
cool to room tem-
perature.
3. Remove the black
protection cap by
hand. (Fig. 71)
4. Insert a 5/3”
or 4 mm Allen
wrench into the
hexagonal key-
way of the screw
(Fig. 7), rotate it
counterclockwise
until it is free and
extract it.
5. Check that the
screw is clean
and if necessary
remove dirt.
6. Flip the screw. (Fig.
73)
7. Using the Allen
wrench as shown
in Figure 74, rotate
the screw clock-
wise and tighten
until snug.
WARNING: Do
not overtighten
the screw. Rec-
ommended to grip the wrench by
the short side.
8. Verify that if the conversion is from NG to LP, the screw
must be reassembled with the red o-ring visible. (Fig.
75)
()
,/
#/
REMOVESCREW
Figure 71
()
,/
#/
!LLENWRENCH
Figure
72
()
,/
#/
TURNSCREW
Figure 73
()
,/
#/
!LLENWRENCH
Figure 74
(
)
,/
(
)
,/
LP Configuration
Natural Gas
Configuration
CO141
O-ring configuration
6/07
Red O-ring Visible
Red O-ring NOT Visible
CO141
Figure 75
9. Replace the black protection cap.
WARNING: Check that also the pilot and
main burner injectors are appropriate for the
gas type.
Содержание Radiance RADVTBD