16
16
Radiance
®
Direct Vent Gas Heater
30004967
ST347a
JUV
FK28
rheostat install
9/21/00
Rheostat
Retaining Collar
Rheostat Knob
ST347a
Fig. 18
Attach the fan rheostat.
Rheostat
Install the Optional Fan - RADVT Series
If you are installing the optional convection Fan Kit #767
(FK6), continue here. It is easiest to install fan kit before
connecting gas line. If you are not installing a Fan Kit, go
to Page 17, Venting System Assembly.
1. The fan kit includes a Blower Assembly and a Rheostat
Assembly, connected by a cable. (Fig. 15) The Blower
Assembly mounts to the bottom rear of the stove, and
the Rheostat mounts to the valve coverplate. The as-
sembly includes a ‘snapstat’ which automatically turns
the fan On (or Off) above (or below) approximately 109°.
The Rheostat also provides a range of fan speed set-
tings from Off (which overrides the snapstat function) to
High. Unpack and inspect the Blower assembly. Confirm
that the fan spins freely.
ST147
RDV40 remove rear shroud
10/99
Fig. 16
Remove rear shroud.
ST147
ST473a
Fan parts
#2767 FK26
9/29/00
Not
Used On
Radiance
Snapstat
Bracket
Snapstat/
Extension
Assembly
Rheostat
Assembly
ST473a
Blower
Assembly
Fig. 15
Fan kit components.
WARNING
This appliance is equipped with a three-prong
(grounded) plug for your protection against shock
hazard and should be plugged directly into a
properly grounded three-prong receptacle. Do not
cut or remove the grounding prong from this plug.
. Remove the rear shroud panel (Fig. 17) and fasten the
blower assembly to the firebox back with the two bolts
provided. (Fig. 17)
3. Attach the snapstat assembly to the snapstat bracket
with two sheet-metal screws. Attach the snapstat bracket
to the side shield. (Fig. 17)
4. The rheostat control switch attaches to the left side of
the valve bracket at the front of the stove. (Fig. 18)
•
Remove retaining nut from shaft of rheostat. (if pre-
installed)
ST149
rdv attach fan assy
10/99
Side Shield
Snapstat
Bolts
ST149
Fig. 17
Attach blower assembly and snapstat.
•
Insert the rheostat through the hole in the back of
the left side of the valve bracket, aligning the locator
pin with the smaller hole in that bracket.
•
Thread the retaining nut onto the shaft of the rheo-
stat, tightening with a wrench. Do not overtighten.
•
Attach the control knob to the rheostat shaft.
•
Use the wire tie to secure the fan and rheostat wire
harnesses together.
Содержание Radiance RADVTBD