14
Intrepid 1640 Woodburning Stove
30000830
Stove in
Corner
Stove Installed Par-
allel to Wall
Unprotected Surfaces
1. Shielding for a top exit stove must include the stove rear heat shield insert to protect the area behind the flue collar.
2. Chimney connector heat shields, in an installation that goes through a combustible ceiling, must extend to 1” (25mm) below
the ceiling heat shield, which is 22” (559 mm) in diameter. The ceiling heat shield should be 24 gauge or heavier sheet metal,
centered on the chimney connector, and mounted on non-combustible spacers.
3. Rear Exit—horizontal connection from flue collar directly back through wall.
4. The ceiling heat shield required when chimney connector shields are used should meet the wall protector. This will require
trimming the ceiling shield along the line of intersection with the wall protector.
5. Requires the Flue Collar Shield Insert installed on the stove.
Protected Surfaces
Chimney Connector Clearance
Stove Clearance
(I) 12”
(305 mm)
48” (1219 mm)
Front Clearance to Combustibles
Side Rear Corners
(NA)
(NA)
(Q) 9”
(229 mm)
(P) 12”
(305 mm)
(J) 12”
(305 mm)
(K) 9”
(229 mm)
(L) 10”
(254 mm)
(I) 12”
(305 mm)
(H) 16”
(406 mm)
(N) 14”
(356 mm)
(H) 16”
(406 mm)
(G) 24”
(610 mm)
(M) 24”
(610 mm)
(G) 24”
(610 mm)
12” (305 mm)
5” (127 mm)
4
10” (254 mm)
26 “ (660 mm)
*
*
12” (305 mm)
Side Rear Corners
Stove Installed Par-
allel to Wall
Stove in
Corner
Use the chart below together with the diagrams on the next page to determine the required clearance for your par-
ticular installation.
Stove clearances are measured from the top plate to the combustible surface.
Chimney connector clearances are measured from the connector surface.
Intrepid 1640 Clearance Chart
Top Exit, Single-wall
Chimney Connector with
Connector Heat Shields
1, 2, 4
Rear Exit
3
Top Exit, Double-wall
Chimney Connector
5
Single-wall Chimney
Connector, without
Connector Heat Shields
Single-wall Chimney
Connector, with Connector
Heat Shields
Double-wall Connector
5
(D) 12”
(305 mm)
(E) 16”
(406 mm)
(F) 10”
(254 mm)
(C) 20”
(508 mm)
(B) 26”
(660 mm)
(A) 22”
(559 mm)
Top Exit, Single-wall
Chimney Connector
without Connector Shields
f i r e - p a r t s . c o m