background image

16

Intrepid 1640 Woodburning Stove

30000830

You will need the following tools to assemble the In-
trepid:
• 9/16” open end wrench  • safety glasses & gloves
• flat head screwdriver 

• power drill w/ 1/8” (3mm) bit

Caution. The Intrepid is very heavy. Do not attempt 
to handle the stove without assistance. 

Unpack the Stove

1. Remove the shipping straps and plastic wrap.
2. Inspect the stove and contents for shipping damage 

or missing parts. Immediately notify your dealer of 
any damage. Do not install this stove if any damage 
is evident or any parts are missing.

  Firebox Contents:

  •  Smokeshelf Plate 
  •  Upper Firebricks, 3
  •  Hardware Bag
 

Hardware Bag contents:

  • Stove Legs, 4 
  • Hex Head Leg bolts with washers, 4
  • #10 x 1/2” sheet metal screws,  3
  • Door Handle Holder
  • 5/32” Allen Wrench
  • 1/8” Allen Wrench
  • Furnace Cement, 3 oz. Tube
  • Owner’s Registration Card 
  • Touch-up Paint (Porcelain enamel stoves only)
3. Remove any wooden or cardboard packing material 

from the stove.

Install Stove Legs

Remove and discard the four slot-head screws from 
the stove bottom. Have an assistant tilt the stove while 
you install first the back and then the front legs using  
the four 3/8-16 x 1” hex head bolts with 3/8” washers 
from the parts bag.  The shoulder of the legs should 
seat within the locator tabs cast into the stove bottom 
at each corner.  Tighten the bolts with the 9/16” wrench. 

CAUTION: Overtighening can strip tapped threads.

Install the Door Handle Holder between the Right Front 
leg and the stove. (Fig. 27)

Assembly

Install the Bottom Heat Shield

The optional # 0307 Bottom Heat Shield must be used 
in the U.S. and Canada in any installation on a floor that 
is not comprised of unpainted cement on earth. 
1. Loosen each leg bolt enough to slip the shield C-

Clips onto the bolt. 

2. Orient the Bottom Heat Shield so that the longer 

edge is at the front.  Refer to Figure 28. Attach the 
Bottom Heat Shield to the C-Clips using the wing-
bolts 

3.  Re-tighten the leg bolts

ST568

Install

bottom heat shield

clips

12/00

Fig. 27 

 Install Legs and optional Bottom Heat Shield. The 

Handle Holder should be at the right front.

Door Handle 
Holder

C-Clip 

Wingbolt

Bottom Heat Shield

ST568

10

³⁄₄

"

(273mm)

9

³⁄₄

"

(248mm)

ST512

Attach

bottom heat

shield

11/00

Fig. 28

  Bottom Heat Shield orientation.

ST512

f i r e - p a r t s . c o m

Содержание Intrepid 1640

Страница 1: ...LURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Do Not D...

Страница 2: ...hat you hire a professional solid fuel stove technician to install your Intrepid or to advise you on the installation should you attempt to install it yourself Consult the authority having local juris...

Страница 3: ...e content of the fuel used as well as the design construction and climatic location of your home Figures shown are based on maximum fuel consumption obtained under laboratory conditions and on average...

Страница 4: ...re the bases for many national codes They are nationally recognized and are accepted by most local authorities Your local dealer or your local building of cial may have a copy of these regulations IMP...

Страница 5: ...the ue Chimney connectors are used only to make the connection from the stove to the chimney They are for interior use only Double wall connectors must be tested and listed for use with solid fuel bur...

Страница 6: ...ns Securing the Single wall Connector to a Prefabricated Chimney Follow the installation instructions of the chimney manufacturer exactly Special adaptors are available from your local dealer to make...

Страница 7: ...lding inspector before you begin Also check with the chimney connector manu facturer for any speci c requirements Consult with your dealer regarding special connection components available for use as...

Страница 8: ...ired 18 457mm clearance around the connector The resulting space must remain empty A ush mounted sheet metal cover may be used on one side only If covers must be used on both sides each cover must be...

Страница 9: ...um oor protector requirement from the front of the stove 16 416 mm from the front in the United States and 18 457 mm from the front in Canada The optional 3 75 mm legs may be used only on hearths that...

Страница 10: ...or chimney connector and nearby walls oors the ceiling and any other xed combustible surface Keep furnishings and other combustible materials away from the stove as well In general a distance of 48 12...

Страница 11: ...D C E A D ST509a Wall shield BB 11 00 ST509a Fig 19 Corner installation vertical chimney connector two wall shields B B A D A C C A D A ST510 Wall shield cc 11 00 A 1 25mm B 34 864mm C 48 1219mm D 35...

Страница 12: ...om the stove s top plate With a ventilated shield this clearance may be reduced safely to 14 357mm Unprotected top trim B protruding 2 51mm or less from the face of the replace must be a minimum of 24...

Страница 13: ...Alcove side view 11 10 00 djt Metal stud A This area from 62 to 65 must be covered with a non combustible material 7 16 Durock or equivalent Fig 23 Alcove side section Joist shield supplied by chimne...

Страница 14: ...Chimney Connector Clearance Stove Clearance I 12 305 mm 48 1219 mm Front Clearance to Combustibles Side Rear Corners NA NA Q 9 229 mm P 12 305 mm J 12 305 mm K 9 229 mm L 10 254 mm I 12 305 mm H 16 4...

Страница 15: ...s 11 00 P Q M N C N A N A Top Exit No Chimney Connector Shields Rear Exit Top Exit with Chimney Connector Shields or Double wall Chimney Connector Stove Installed Par allel to Wall Stove in Corner Unp...

Страница 16: ...Have an assistant tilt the stove while you install rst the back and then the front legs using the four 3 8 16 x 1 hex head bolts with 3 8 washers from the parts bag The shoulder of the legs should se...

Страница 17: ...s provided in the kit to attach the adaptor to the center mounting ange at the bottom of the Rear Shroud Install Smokeshelf Firebricks Look inside the rebox and locate the position for the Smokeshelf...

Страница 18: ...insulated and weather tight poor draft may result from insuf cient air in the house In such cases a slightly opened window near the stove on the windward side of the house will pro vide the fresh air...

Страница 19: ...t can be broken with a sharp blow from a hammer or from the thermal shock of rapid and extreme temperature change The cast plates expand and contract with changes in tempera ture When you rst begin us...

Страница 20: ...and ULC S627 for Canada Your stove may be used as a replace with the front doors open or removed only when the spark screen is placed correctly in the opening to protect against the possibility of spa...

Страница 21: ...rd from the rebricks to the grate where it will fall into the ashpan for easy removal Remove ash before it reaches the top of the ash pan Check the level at least once a day and before each re fueling...

Страница 22: ...st clean the areas to be painted with a wire brush Then touch up the stove with Vermont Castings high tem perature stove paint Apply the paint sparingly and keep in mind that two light coats of paint...

Страница 23: ...f necessary Failure to keep the chimney and connector system clean can result in a serious chimney re When wood is burned slowly it produces tar organic vapors and moisture that combine to form creoso...

Страница 24: ...on this Close and lock the door or damper on a slip of paper and then try to pull the paper out If the paper pulls out with little or no resistance the gasket isn t snug enough at that spot If adjusti...

Страница 25: ...temperatures Because the insulation is less dense than masonry the inner steel liner warms up more quickly than a masonry chimney Although steel chimneys are not as attractive as their masonry counter...

Страница 26: ...wood is Purchase your fuel from a reputable dealer Creosote Creosote is a by product of low temperature stove operations weak draft or both It is a tar that results when unburned gases condense insid...

Страница 27: ...eed to be attentive in timing the use of the other appliances If you need to crack a nearby window or door to enable the chimney to pull well you should install an outside air intake to bring combusti...

Страница 28: ...de See Chart Pg 29 4 Secondary Air Manifold Right 30000819 5 Left Side See Chart Pg 29 6 Secondary Air Manifold Left 30000820 7 1 4 20 x 2 1 4 CS Hex Hd Screw 2 1201403 8 Secondary Air Tube A 30000825...

Страница 29: ...Flue Collar Heat Shield 30000863 69 Rear Convection Shroud 30000826 70 10 x 1 2 Blk Phillips Sheetmetal Screw 2 1202058 72 Faucet Stub Chrome w Shaft 5004245 73 Ashpan Front 1306493 74 Ashpan Handle...

Страница 30: ...30 Intrepid 1640 Woodburning Stove 30000830 fire parts com...

Страница 31: ...y relevant information or circumstances regarding determi nation of failure 5 In addition the owner must return the failed catalyst Exclusions Limitations 1 This warranty is transferable however proof...

Страница 32: ...CFM Specialty Home Products 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com CFM Specialty Home Products fire parts com...