background image

20306750  3/15  Rev. 3

 

Designer Series Direct Vent Gas Fireplace
Installation and Operating Instructions

Models: STLDVP(N/P)SC, PFLDV(N/P)PSC, CRLDVP(N/P)SC, CLLDVP(N/P)SC

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for 

future reference.

• 

Do not store or use gasoline or other 
fl ammable vapors and liquids in the 
vicinity of this or any other appliance.

• 

WHAT TO DO IF YOU SMELL GAS

 

– Do not try to light any appliance.

 

– Do not touch any electrical switch; do 

not use any phone in your building.

 

– Leave the building immediately.

 

– Immediately call your gas supplier from 

a neighbor's phone. Follow the gas 
supplier's instructions.

 

– If you cannot reach your gas supplier, 

call the fi re department.

• 

Installation and service must be performed 
by a qualifi ed installer, service agency or 
the gas supplier.

WARNING: Improper installation, adjustment, 
alteration, service or maintenance can cause 
injury or property damage. Refer to this manual. 
For assistance or additional information consult 
a qualified installer, service agency or the 
gas supplier.   

This appliance may be installed in an aftermarket,* 
permanently located, manufactured home (USA 
only) or mobile home, where not prohibited by 
local codes.

This appliance is for use only with the type of gas 
indicated on the rating plate. This appliance is 
not convertible for use with other gases, unless 
a certifi ed kit is used. 

*  Aftermarket: Completion of sale, not for purpose of resale, from 

the manufacturer. 

 WARNING: 
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly 
could result in serious injury, death or 
property damage.

DANGER

HOT GLASS 

WILL

CAUSE BURNS

.

DO NOT TOUCH GLASS

UNTIL COOLED.

NEVER ALLOW CHILDREN

TO TOUCH GLASS.

A barrier designed to reduce the risk of burns from 

the hot viewing glass is provided with this 

appliance and shall be installed.

CERTIFIED

S

AFETY

 

B

ARRIER

Содержание CLLDVPNSC

Страница 1: ...G Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer ser...

Страница 2: ...lation 34 Wall Switch Installation 34 Signature Command Wiring Diagram 35 Optional Fan Blower Systems 36 Signature Command Single Blower BLOTSTSC 36 Automatic Dual Thermostat Blower BLOTBLDV 37 Automa...

Страница 3: ...ctions for future reference IMPORTANT SAFETY INFORMATION This fireplace is a vented product This fireplace must be properly installed by a qualified service person The glass door must be properly seat...

Страница 4: ...Direct Vent type appliances draw all combustion air from outside of the dwelling through the vent pipe These appliances have been tested by CSA and found to comply with the established standards for D...

Страница 5: ...ed without deration for elevations up to 4 500 feet 1 370 m above sea level For elevations above 4 500 feet 1 370 m in USA installations must be in accordance with the current ANSI Z223 1 NFPA 54 and...

Страница 6: ...mm 25 6M 654 mm 3356QE 840 mm 156M 32 mm 34 864 mm 11 6M 298 mm 3 6M 95 mm 24 610 mm 27 6M 705 mm 46 6 1178 mm 38 6QE 979 mm 7 6 200 mm 12 305 mm 47 6 1216 mm 41 6 1064 mm 37 6 962 mm 23 584 mm 156M...

Страница 7: ...m 2856M 718 mm 25 6M 654 mm 7 6 200 mm 556 130 mm 156 29 mm 3356QE 840 mm 38 6QE 979 mm 46 6 1178 mm 7 6 200 mm 12 305 mm 47 6 1216 mm 41 6 1064 mm 37 6 962 mm 23 584 mm 35 6QE 903 mm 2856M 718 mm 156...

Страница 8: ...TLDV See thru Framing If using 5 8 drywall remove noncombustible supports rotate 180 and reinstall to achieve 5 8 depth The fireplace must be secured to the floor and or to framing studs as shown in F...

Страница 9: ...positioned slightly inwards If using 5 8 drywall remove framing tabs and re install on 2nd set of holes positioned slightly inwards The fireplace must be secured to the floor and or to framing studs a...

Страница 10: ...le Material Fold Outer Tabs and Nail to Framing Members Figure 7 PFDV Peninsula Framing If using 5 8 drywall remove framing tabs and re install on 2nd set of holes positioned slightly inwards The fire...

Страница 11: ...elow top of standoffs NOTE When planning your framing and installation keep in mind that the gas line and electric power come in on the same end of the fireplace Refer to Figures 2 3 4 for fireplace d...

Страница 12: ...to heat from appli ance Y B C Y X D A Island C and Room Divider D installation is possible as long as the horizontal portion of the vent system X does not exceed 20 610cm See details in Venting Secti...

Страница 13: ...installed on a carpet tile or other combustible material other than wood flooring If installed on carpet or vinyl flooring the appliance shall be installed on a metal wood or noncombustible material p...

Страница 14: ...ns Read all instructions completely and thoroughly before attempting installation Failure to do so could result in serious injury property damage or loss of life Operation of improperly installed and...

Страница 15: ...f the intake box and remove the pipe and gasket Figure 13 5 Replace the flue pipe to top of firebox Ensure the gasket is in place and undamaged Secure with six 6 screws Figure 14 6 Place the flue pipe...

Страница 16: ...etrates outside wall A minimum 1 clearance to combustibles permitted all around flue at outside wall FP2819 WARNING Horizontal sections of this vent system require a minimum of 3 clearances to combust...

Страница 17: ...combustible material Maintain proper clearances to all combustible materials WARNING Alwaysmaintainminimumclearancesaround vent systems The minimum clearances to combustibles for horizontal vent pipe...

Страница 18: ...liances 100 000 BTU h 30kW 6 15cm for appliances 10 000 BTU h 3kW 9 23cm for appliances 10 000 BTU h 3kW and 50 000 BTU h 15kW 12 30cm for appliances 50 000 BTU h 15kW C Clearance to permanently close...

Страница 19: ...nt Pipe Dimensions in Feet 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 2 4 6 8 10121416 1820 eg A 323 4 to Center of Horizontal Pipe Outside Corner Inside Corner Termination Clearances Ter...

Страница 20: ...ions for further instructions 3 Locate and cut the vent opening in the wall For com bustible walls first frame in opening Combustible Interior Walls Cut a 121 2 x 101 2 hole through the interior wall...

Страница 21: ...izontal Termination HOT Cut Vinyl Siding Away to Fit Standoff Standoff 1250 or 5DT VS Not required for Vermont Castings Group termination Termination Bolt Wood Screw Nut Apply Mastic to all Four Sides...

Страница 22: ...the top of the Transition Elbow to the face of the finished outside wall or the mounting flange of the termination The maximum number of 90 elbows per side wall installation is three 3 Figure 25 If a...

Страница 23: ...wall frame Figure 25 Noncombustible Walls Hole opening should be 81 2 216 mm in diameter 2 The center of the hole should line up with the center line of the horizontal rigid vent pipe end Allow 1 4 mi...

Страница 24: ...el a minimum 24 vertical rise is nec essary The maximum horizontal run with the 24 vertical pipe is 36 This measurement is taken from the collar of the fireplace or transition elbow to the face of the...

Страница 25: ...and bottom until the flue penetrates the outside wall A minimum 1 clearance all around the flue is acceptable at this point of penetration Unless the vertical run is 71 2 feet or higher form floor of...

Страница 26: ...gure 37 Offset with Wall Strap and 45 Elbows Roof Flashing Wall Strap 45 Elbows Ceiling Firstop FP1669 FLAT CEILING INSTALLATION 1 Cut a 101 2 267 mm square hole in the ceiling using the locating hole...

Страница 27: ...45 elbows instead of 90 elbows The 45 elbow offers less restriction to the flow of the flue gases and intake air 5 Place the flashing over the pipe section s extending through the roof Secure the bas...

Страница 28: ...le vent pipe and push out of the way 3 Pull and extend the inner flexible vent 4 Slide the inner vent onto the adapter collar for a minimum 13 4 overlap 5 Locate the clamp at approximately 3 4 from th...

Страница 29: ...nect the 8 flexible vent to the termination ring as in Figure 45 3 Review Figure 45 for proper overlap and clamp placement 4 Three each self penetrating screws are drilled opposite one another and bel...

Страница 30: ...7 Rigid Pipe Length Flex to Pipe Adapter DVFFA 8 Gear Clamp 13 4 Flexible Pipe and Adapter Outer Collar Overlap UL1777 Flex Vent Figure 48 Typical Pipe Connection Gear Clamp Screws 3 Places equidista...

Страница 31: ...an acceptable alternative to test gauge connection Purchase the CSA design certified equip ment shutoff valve from your dealer For propane LP connections only the installer must supply an external reg...

Страница 32: ...m valves CAUTION A manual shutoff valve must be installed upstream of the appliance Union tee and plugged 1 8 NPT pressure tapping point should be installed upstream of the appliance Figure 51 CAUTION...

Страница 33: ...eries are used for back up during power outages 2 The Signature Command System can also be operated without A C power The system can run on four 4 AA batteries for approximately six 6 months under nor...

Страница 34: ...beyond the 15 ft wire cable provided If a longer distance is required the 15 ft may be extended up to 30 ft maximum by using two 2 SCSWEK cables plugged together Route the wire from junction box to l...

Страница 35: ...Black Optional Aux Green Plug in Connector Connector Pin To Control Board Input 300 Watt Max Each Optional A C Module Replaces 6V Adapter When Used 6V AC Adapter Control Board RF Receiver ON OFF Butto...

Страница 36: ...only be performed by a qualified licensed electrician Main power supply must be turned off before connecting the fan to the main electrical power supply or performing service BLOTSTSC SIGNATURE COMMAN...

Страница 37: ...Figure 56 BLOTBLDV Blower Wiring Diagram FP2685 Before installing the blower wire the receptacle into an electrical circuit This should be done before framing the fireplace Wire with minimum 60 C wir...

Страница 38: ...ar of their corresponding tabs on the firebox Then proceed to remove the glass frame by following the steps below 1 Remove access panel by lifting up and out 2 Release two clamps on bottom of fireplac...

Страница 39: ...e burner slots To better enable the gas to permeate the rock wool apply the rock wool in light dime size fluffy pieces WARNING Do not use the entire bag of rock wool to cover the burner This could cau...

Страница 40: ...toward the nearest glass The other end of the log rests on the second tine from the end closest to the pilot Figure 63 LOG PLACEMENT 1 Hold log 1 with the rounded end opposite the pilot NOTE Log 1 is...

Страница 41: ...nt Gas Fireplace FIREPLACE INSTALLATION 5 Place log 5 on the key provided on log 4 Rest the other end of the log on the false bottom hearth just outside of the grate It should be almost touching the e...

Страница 42: ...1 Remove screen from packaging 2 Align the three 3 slots in the top of the screen with the three 3 tabs on top of the firebox These are the tabs on which the glass frame hangs Slide the screen down on...

Страница 43: ...phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not f...

Страница 44: ...llow B in the safety information on page 43 If you do not smell gas go to next step 4 Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates the system is r...

Страница 45: ...cation for Transmitter X X X X X Child Proof Lock out X X X X X LCD Backlight X X X X X Security Codes 16 X X X X X Countdown 6 hr Timer X X X Standard Thermostatic Control Mode X X X Smart Mode Therm...

Страница 46: ...nds when the master switch Shutoff on the main burner is off RF Remote Receiver Push the RF receiver On Off button on the control board RF OFF On Off Beep once for ON and beep twice for OFF Learn Remo...

Страница 47: ...ame height 2 Press the OFF button to decrease flame height The first two presses will decrease the flame height to medium and low Self Diagnostics Chart The Command Center has a self diagnostic LED en...

Страница 48: ...t or foreign material with a brush or vacuum BURNER FLAME The flames from the burner should be visually checked as soon as the heater is installed and periodically during normal operation In normal op...

Страница 49: ...teri als may be used Handle glass door with care to avoid striking or scratch ing it on hard objects To clean glass door follow Glass Removal procedure outlined in the Final Installation section Film...

Страница 50: ...k gas supply Go through Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low...

Страница 51: ...signer LDV Part No 1 Glass Frame Assembly 2 2 1 20302401 2 Access Panel 2 2 1 20302126 3 Glass Frame Assembly Short 1 1 20302151 4 Access Panel Short 1 1 20302127 5 Grate 1 1 1 20301124 6 Large Safety...

Страница 52: ...52 20306750 Designer Series Direct Vent Gas Fireplace REPLACEMENT PARTS SIGNATURE COMMAND SYSTEM 1 12 2 3 4 15 13 7 16 11 5 9 6 8...

Страница 53: ...18 w Shutoff Valve 1 69D0030 69D0030 12 Pilot SCS 1 80D0006 13 Grommet 1 73D0189 73D0189 14 Sealant 1 28D0149 28D0149 15 Control Board SCS 1 80D0018 80D0019 16 Command Center SCS 1 80D0005 80D0005 17...

Страница 54: ...20302433 3 Log 3 1 20302434 4 Log 4 1 20302435 5 Log 5 1 20302436 LOGS 5 1 2 3 4 BRICK 1 2 3 4 Herringbone Brick Traditional Brick Ref Description Cottage Red Olde English Vintage Brown 1 End Wall Tr...

Страница 55: ...20306750 55 Designer Series Direct Vent Gas Fireplace REPLACEMENT PARTS VENT COMPONENTS HOT 1 2 3 4 5 6 9 7 8 11 10...

Страница 56: ...DT 09 3 6 12 Pipe Length galvanized 46DVA 12 906 4DT 1 3 6 24 Pipe Length galvanized 46DVA 24 904 4DT 4 3 6 36 Pipe Length galvanized 46DVA 36 903 4DT 36 3 6 48 Pipe Length galvanized 46DVA 48 902 4DT...

Страница 57: ...24 1204 5DT 24 5D24 3 4 36 Pipe Length 58DVA 36 1203 5DT 36 5D36 3 4 48 Pipe Length 58DVA 48 1202 5DT 48 5D48 4 4 81 2 Pipe Extension 58DVA 08A 5DT AJ 4 4 16 Pipe Extension 58DVA 16A 5 4 45 Elbow 58DV...

Страница 58: ...Up and Out Starter Kit w 40 Flex Pipe Firestop Cool 7FDVSCTK Touch Termination w Siding Shield and 2 ea Clamp Bands Twist Lock Pipe 20 Termination Pipe 8 pack 7TDVP20 8 10 16 Adjustable Termination Pi...

Страница 59: ...e pack 7TDVP20 30 Flex Pipe single pack 7FDVP30 12 18 Adjustable Vent Length 7TDVP1218 35 64 Adjustable Vent Length 7TDVP3564 8 Vent Pipe 4 pack 7TDVP8 4 12 Vent Pipe 4 pack 7TDVP12 4 24 Vent Pipe 4 p...

Страница 60: ...thirty 30 days to comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed MASSACHUSETTS...

Страница 61: ...Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly...

Страница 62: ...62 20306750 Designer Series Direct Vent Gas Fireplace This page left blank...

Страница 63: ...20306750 63 Designer Series Direct Vent Gas Fireplace This page left blank...

Страница 64: ...09 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com EFFICIENCY RATINGS MODEL ENERGUIDE RATINGS FIREPLACE EFFICIENCY PERCENTAGE D O E AFUE PERCENTAGE Natural Gas 69 7 67 0 Liquid P...