48
20306750
Designer Series Direct Vent Gas Fireplace
CLEANING AND MAINTENANCE
BURNER, PILOT AND CONTROL COMPART-
MENT
Keep the control compartment, logs, and burner areas
surrounding the logs clean by vacuuming or brushing at
least twice a year. Make sure the burner porting, pilot air
opening and burner air opening are free of obstructions
at all times.
PILOT FLAME
The fl ames from the pilot should be visually checked as
soon as the heater is installed and periodically during
normal operation.
The pilot fl ame must always be pres-
ent when the fi replace is in operation. Figure 66
. The
pilot fl ame has four distinct fl ames, one engulfi ng the
thermopile, one engulfi ng the sensor, and the other two
reaching to the main burners.
BURNER
Inspect area around the injector. Remove any lint or foreign
material with a brush or vacuum.
BURNER FLAME
The fl ames from the burner should be visually checked
as soon as the heater is installed and periodically during
normal operation. In normal operation, at full rate, and after
operating for about 15 to 30 minutes, the fl ame should be
yellow and slightly taller than the rear log.
Figure 67
If the fl ame is blue and only in the center, turn off unit and
let cool. After unit is cool, remove logs and check to make
sure the back holes in the burner are not covered with rock
wool. If the back holes are clear, add more rock wool to the
center of the burner. Replace logs.
NOTE:
The type of installation, vent system confi guration,
and wind effects may cause the fl ame patterns to vary.
Figure 67 -
Burner Flame Appearance
WA
R
N
IN
G
Turn off gas before servicing fi replace. It
is recommended that a qualifi ed service
technician perform these check-ups at the
beginning of each heating season
Figure 66 -
Pilot Flame
Thermopile
Sensor
FP2453