38
20306750
Designer Series Direct Vent Gas Fireplace
FIREPLACE INSTALLATION
CA
U
T
IO
N
Each clamp has a quick spring force. When
reinstalling clamps, keep fi ngers clear.
Figure 58 -
Remove Screen Barrier and Glass Frame
GLASS FRAME REMOVAL
NOTE:
You must fi rst remove the safety barrier before you
remove the glass frame. To remove the barrier, simply lift
up and pull out until the slots on the screen are clear of
their corresponding tabs on the fi rebox. Then proceed to
remove the glass frame by following the steps below.
1. Remove access panel by lifting up and out.
2. Release two clamps on bottom of fi replace.
Figure 58
3. Tilt glass frame out and lift glass frame up until it clears
three tabs on top of fi replace.
4. Set glass frame aside.
DANGER
HOT GLASS
WILL
CAUSE BURNS
.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this
appliance and shall be installed.
Safety Barrier
Access Panel
Glass Frame