CDVSC7 & CDV7 Series Gas Fireplace
69D3011
9
pRe-InSTallaTIon InFoRMaTIon
BeFoRe you STaRT
Read this homeowner manual thoroughly and follow all
instructions carefully. Inspect all contents for shipping
damage and immediately inform your dealer if any damage
is found. Do not install any unit with damaged, incomplete,
or substitute parts. Check your packing list to verify that
all listed parts have been received. You should have the
following:
•
Fireplace (Firebox and Burner System)
•
Log Set
•
Volcanic Rock
•
Rock Wool
ITeMS RequIReD FoR InSTallaTIon
Tools:
Building Supplies:
•
Phillips Screwdriver
•
Framing Materials
•
Hammer
•
Wall Finishing Materials
•
Saw and/or saber saw
•
Level
•
Electric Drill and Bits
•
Tee Joint
•
Pliers
•
Measuring Tape
•
Square
•
Pipe Wrench
•
Caulking Material (Noncombustible)
•
Fireplace Surround Material (Noncombustible)
•
Piping Complying with Local Codes
•
Pipe Sealant Approved for use with Propane/LPG
(Resistant to Sulfur Compounds)
The firebox may be installed directly on a combustible floor
or raised on a platform of an appropriate height. When the
firebox is installed directly on carpeting, tile, or other com-
bustible material, other than wood flooring, the firebox shall
be installed on a metal or wood panel extending the full
width and depth of the enclosure.
w
a
R
n
In
G
Do not fill spaces around firebox with
insulation or other materials. This could
cause a fire.
FIReplaCe loCaTIon
Plan for the installation of your appliance. This includes
determining where the unit is to be installed, the vent con-
figuration to be used, framing and finishing details, and
whether any optional accessories (i.e. blower, wall switch,
or remote control) are desired. Consult your local building
code agency to ensure compliance with local codes, includ-
ing permits and inspections.
The following factors should be taken into consideration:
•
Clearance to side-wall, ceiling, woodwork, and windows.
Minimum clearances to combustibles
must be main-
tained.
•
This fireplace may be installed along a wall, across a
corner, or use an exterior chase. Refer to
Figure 4
for
suggested locations.
•
Location should be out of high traffic areas and away
from furniture and draperies due to heat from appli-
ance.
•
Never obstruct the front opening of the fireplace.
•
Do
not
install in the vicinity where gasoline or other
flammable liquids may be stored.
•
Vent pipe routing. See
Venting
section found in this
manual for allowable venting configurations.
•
These units can be installed in a bedroom. See National
Fuel Gas Code ANSI Z33.1/NFPA 54 — (current
edition), the Uniform Mechanical Code — (current edi-
tion), and Local Building Codes for specific installation
requirements.
FIReBox FRaMInG FoR CDVR
Firebox framing can be built before or after the appliance
is set in place. Construct firebox framing following
Figure
2
for your specific installation requirements.
Refer to Figure
2
for firebox dimensions. The framing headers may rest on
the top of the firebox standoffs.
Do not bring headers
below top of standoffs. noTe: CDVR33SC7 &
CDVR33117 do not have standoffs.
The firebox may be installed directly on a combustible floor
or raised on a platform of an appropriate height. When the
firebox is installed directly on carpeting, tile, or other com-
bustible material, other than wood flooring, the firebox shall
be installed on a metal or wood panel extending the full
width and depth of the enclosure.
FIReBox FRaMInG FoR CDVT
Firebox framing can be built before or after the appliance
is set in place. Construct firebox framing following
Figure
3
for your specific installation requirements.
Refer to Figure
3
for firebox dimensions. The framing headers may rest on
the top of the firebox standoffs.
Do not bring headers
below top of standoffs.
Figure 4 -
Locating Gas Fireplace
Y
E
A
B
C
D
F
Y
B
X
LU584-1
Locating unit
2/4/99 djt
** Island (C) and room divider (D) installation is possible as long
as the horizontal portion of vent system (X) does not exceed
0'.
* When you install your fireplace in (D) room divider or (E) flat on
wall corner positions (Y), a minimum of 4" clearance must be
maintained from perpendicular wall and front of fireplace.
A Flat on
Wall
B Cross
Corner
C Island**
D Room
Divider*
E Flat on
Wall
Corner*
F Chase
Installation
Y 4"
Minimum